(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

NARVCTF PSE Supported (NARVCTF-0.75-10-13)

NARVCTF PSE Supported NARVCTF-0.75-10-13

Click this image to zoom it.

Move the mouse over the image to zoom

  • Volume Discount

600 V PSE standard robot cable. It can also be used inside cable carriers.

  • PSE Law
  • Oil-Resistant
  • Strand Wire
  • Thinned Wire Conductor
  • 300 V

* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.

PDF

Part Number

Configured Part Number is shown.

NARVCTF-0.75-10-13

Specifications

NARVCTF PSE Supported:Related Image
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".

Model NumberSection Area
(mm2)
Number of CoresTotal Length *3
or
Specified Length
NARVCTF0.521
~
100
(Specify 1 m
Increment)
/
500
/
1000
3
4
6
8
10
12
16
20
30
0.752
3
4
6
8
10
12
16
1.252
3
4
6
8
10
12
16
22
3
4
6
8
10
12


Be sure to read the following precautions when you place an order.
*Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
*3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).

More Information

NARVCTF PSE Supported:Related ImageNARVCTF PSE Supported:Related Image

NARVCTF PSE Supported:Related Image

NARVCTF PSE Supported:Related Image
NARVCTF PSE Supported:Related Image

Specifications

Model NumberSection Area
( mm2) *1
Number of CoresAWG
Estimate
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished *5
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecificationSample
Provided *4
Allowable Current
A (30°C) *2
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Withstand Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *3Thickness
(mm)
Material *3Thickness
(mm)
Material *3
NARVCTF0.5220Core / Layer
Stranding
26.3049436.1 or less5 or more30007/7/0.121.08N/A0.51PVC2.101.00PVC-
336.60593
447.20683
668.40962
889.701252
101011.001562
121210.801632
161612.002091
202013.202531
303015.8036911.10
0.7521827.1062625.1 or less5 or more30007/10/0.121.300.602.501.00Compliant with
PSE Law
337.50775
448.10894
669.601273
8811.101683
101012.702113
121212.502212
161614.1029121.10
1.2521627.80801015.1 or less5 or more30007/16/0.121.650.602.851.00Compliant with
PSE Law
338.201009
449.001188
6610.701706
8812.402256
101014.4029051.10
121214.103074
161615.703984
221428.70105159.79 or less5 or more30007/25/0.122.100.603.301.00Compliant with
PSE Law
339.2013413
4410.1016011
6612.002339
8814.2031681.10
101016.5040781.20
121216.204346


*1 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*2 The value of allowable current is to be used only as a reference value and is not guaranteed.
*3 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*4 For the outer diameter size of cables, wire sheath (coat), etc., refer to
"Finished Outer Diameter" in the table above. 

Current Reduction Factor
Ambient Temperature (°C)3040506070
Current Reduction Factor1.000.890.750.580.34
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value when the ambient temperature is 40°C, 0.5mm2 2-core:
10 × 0.89 = 8.9 (A)

Part Number
NARVCTF-0.75-10-13
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Number Of Cores
(Core)
Logarithm Finished outer diameter
(mm)
Representative Standard

SGD 205.07

1 Piece(s) 4 Day(s) or more 130.751810012.7PSE

Loading...

  1. 1

Basic Information

Rated Voltage 300V Shield None Properties Oil resistance
Sheath (outer coating) color Navy color Sheath (outer coating) material PVC Insulation body materials PVC
Power supply/signal For power supply Other properties Vibration-resistant, Flexible, Pliable, Elastic

Please check the type/dimensions/specifications of the part NARVCTF-0.75-10-13 in the NARVCTF PSE Supported series.

Similar Part Numbers

Part Number
NARVCTF-0.5-10-11
NARVCTF-0.5-10-12
NARVCTF-0.5-10-13
NARVCTF-0.75-10-14
NARVCTF-0.75-10-15
NARVCTF-0.75-10-16
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Number Of Cores
(Core)
Logarithm Finished outer diameter
(mm)
Representative Standard

SGD 155.27

1 Piece(s) 4 Day(s) or more 110.52010011PSE

SGD 168.98

1 Piece(s) 4 Day(s) or more 120.52010011PSE

SGD 182.67

1 Piece(s) 4 Day(s) or more 130.52010011PSE

SGD 220.48

1 Piece(s) 4 Day(s) or more 140.751810012.7PSE

SGD 235.90

1 Piece(s) 4 Day(s) or more 150.751810012.7PSE

SGD 251.32

1 Piece(s) 4 Day(s) or more 160.751810012.7PSE

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)