(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

NA2501T Earthquake Resistant PSE / UL Supported

NA2501T Earthquake Resistant PSE / UL Supported

Click this image to zoom it.

Move the mouse over the image to zoom

  • Volume Discount

600 V Power cable compatible with Japan / overseas standards

  • c-UL
  • VW-1
  • PSE Law
  • ULAWM
  • For Power Supply
  • Oil-Resistant
  • Strand Wire
  • Thinned Wire Conductor
  • 600 V


● Since it has excellent vibration resistance, it can be used with low-speed movement.  



· UL62 standard has been changed and the maximum cross-sectional area of the conductor is regulated. Due to the change, the conductor configuration is being updated.
AWG12 66/0.26 --> 65/0.26 (change will take effect when the stock has been sold).
· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.

PDF

Part Number

Configured Part Number is shown.

NA2501T-12-4-100

Specifications

NA2501T Earthquake Resistant PSE / UL Supported:Related Image
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh". 
 

Model NumberAWG SizeNumber of CoresTotal Length
or
Specified Length
NA2501T1831
~
100
(Specify 1 m
Increment)
/
500
/
1000
4
163
4
143
4
123
4
104
84
64
44


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* 1 Stock products are indicated with T or A in the price column at right.
* 2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
* 3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).

More Information

NA2501T Earthquake Resistant PSE / UL Supported:Related ImageNA2501T Earthquake Resistant PSE / UL Supported:Related Image

NA2501T Earthquake Resistant PSE / UL Supported:Related Image

Specifications

Model NumberAWG
Size
Number of CoresEstimated
Section Area *1
(mm2)
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished *5
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecificationSample
Provided *4
Allowable Current
A (30°C) *2
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Withstand Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *3Thickness
(mm)
Material *3Thickness
(mm)
Material *3
NA2501T1830.75Core / Layer
Strand
39.71201122.550300077/0.121.22N/A0.85PVC2.921.7PVCPSE Law
ULAWM2501
c-UL
4410.6140101.8
1631.25310.61501514.1123/0.121.543.241.8
4411.4180131.8
1432311.4180199.1784/0.181.913.611.8
4412.5230171.9
1233.5312.9240265.64066/0.262.444.141.9
4414.2300242.0
1045.5416.6440303.63104/0.263.0615.062.1
848421.2700432.347/15/0.324.201.256.702.4
6413.5426.61100561.467/24/0.325.301.78.702.7
4421.4430.11540740.922307/38/0.326.601.710.002.9


*1 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*2 The value of allowable current is to be used only as a reference value and is not guaranteed.
*3 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*4 For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above. 

Wire Core Identification Table
Number of Core WiresColor of Core Lines
3Black 1 / Black 2 / GY
4Black 1 / Black / Black 3 / GY



Current Reduction Factor
Ambient Temperature (°C)304050607080
Current Reduction Factor1.000.910.820.710.580.41
The allowable current shows the value calculated for a single wire aboveground when the ambient temperature is 30°C, and is not guaranteed.
If the ambient temperature is more or less than 30 °C, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 11 x 0.91 = 10.0 (A) when the ambient temperature for 3-core AWG18 is 40 °C

Part Number
NA2501T-12-4-100
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

SGD 1,240.46

1 Piece(s)Available 4 Day(s) or more

Loading...

  1. 1

Basic Information

Overall Length(m) 100 Conductor Cross Section(mm2) 3.5 AWG size(AWG) 12
Number Of Cores(Core) 4 Finished outer diameter(mm) 14.2 Rated Voltage 600V
Shield None Properties Oil resistance Representative Standard PSE / UL / CSA(c-UL)
Sheath (outer coating) color Navy color Grounding Wire GY (green/yellow) colored Sheath (outer coating) material PVC
Insulation body materials PVC Power supply/signal Dual use Other properties Vibration-resistant, Flexible, Pliable

Please check the type/dimensions/specifications of the part NA2501T-12-4-100 in the NA2501T Earthquake Resistant PSE / UL Supported series.

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)