(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

NA3VC UL Standard (NA3VC-16-2-10)

NA3VC UL Standard NA3VC-16-2-10

Click this image to zoom it.

Move the mouse over the image to zoom

  • NA3VC UL Standard NA3VC-16-2-10
  • NA3VC UL Standard NA3VC-16-2-10
  • Volume Discount

300 V cable for fixed signals, ULAWM2517 standard compliant, with excellent oil resistance.

  • VW-1
  • ULAWM
  • Oil-Resistant
  • Strand Wire
  • Twisted Pair
  • 300 V

· This product is compatible with "UL Traceability Program / Processed Wire".
(c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.

Electrical Appliance and Material Safety Law certificate is not obtained.

PDF

Part Number

Configured Part Number is shown.

NA3VC-16-2-10

Specifications

NA3VC UL Standard:Related Image

Model NumberAWG
Size
Core Number / Pair Number * 4
1P = 2 Cores
NA3VC251P
1.5P (3-Core)
2P
3P
4P
5P
6P
7P
8P
10P
12P
15P
18P
25P
32P
231P
2P
3P
4P
5P
6P
7P
8P
10P
12P
18P
25P
211P
2P
3P
4P
5P
6P
7P
8P
10P
192
3
4
6
8
10
12
162
3
4
6
8


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
*3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).
*4 Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering.

More Information

NA3VC UL Standard:Related Image
NA3VC UL Standard:Related Image
NA3VC UL Standard:Related Image

Specifications
Model NumberAWG
Size
Core Number / Pair Number * 1
1P = 2 Cores
Estimated
Section Area
(mm2) * 2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished *6
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecificationSample
Provided* 5
Allowable Current
A (30°C)* 3
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Withstand Voltage
V / 5 Minutes
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *4Thickness
(mm)
Material *4Thickness
(mm)
Material *4
NA3VC251P0.2Twisted Pair23.919.04.4121 or less10 or more20007/0.180.54Tin0.23PVC1.00.9PVCULAWM2517
1.5P (twisted core)34.121.53.80.9
2P45.029.03.50.9
3P65.436.82.91.0
4P85.844.12.61.0
5P106.351.02.41.0
6P126.858.52.21.0
7P146.862.52.11.0
8P167.270.22.01.0
10P208.482.11.81.0
12P248.896.81.71.1
15P309.8119.21.51.2
18P3610.3138.91.41.2
25P5012.1187.31.21.3
32P6413.4235.51.11.4
231P0.324.221.96.371.1 or less10 or more200012/0.180.720.241.20.9
2P45.734.65.00.9
3P66.145.84.21.0
4P86.656.33.71.0
5P107.268.33.41.0
6P128.078.93.11.0
7P148.085.83.01.0
8P168.8100.52.81.1
10P209.8122.62.61.1
12P2410.3144.42.41.2
18P3611.9197.92.11.2
25P5014.1273.81.71.4
211P0.524.730.38.841.9 or less10 or more200020/0.180.920.241.40.9
2P46.547.97.01.0
3P66.861.15.81.0
4P87.476.35.11.0
5P108.092.24.81.0
6P128.9112.54.31.1
7P148.9121.44.11.1
8P169.9138.83.91.1
10P2011.7174.93.61.2
1920.75Twisted Core Layer25.141.011.527.7 or less10 or more200030/0.181.130.241.60.9
335.550.610.01.0
446.060.79.01.0
666.980.07.61.0
887.498.86.61.0
10108.5116.56.21.0
12128.8134.75.71.0
1621.2526.358.817.515.4 or less10 or more200054/0.181.530.282.11.0
336.776.915.21.0
447.294.613.71.0
668.4123.311.61.0
888.9154.710.11.0

NA3VC UL Standard:Related Image


*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material; P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*5 For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.

Current Reduction Factor
Ambient Temperature (°C)30405060708090100
Current Reduction Factor1.000.900.750.730.650.560.440.27
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 4.4 x 0.9 = 3.96 (A) when the ambient temperature for 2-core AWG25 is 40 °C

NA3VC UL Standard:Related Image
Part Number
NA3VC-16-2-10
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Number Of Cores
(Core)
Logarithm Finished outer diameter
(mm)

SGD 31.69

1 Piece(s) 4 Day(s) or more -101.25162-6.3

Loading...

  1. 1

Basic Information

Rated Voltage 300V Shield None Properties Oil resistance
Representative Standard UL Sheath (outer coating) color Navy color Sheath (outer coating) material PVC
Insulation body materials PVC Power supply/signal For signals

Please check the type/dimensions/specifications of the part NA3VC-16-2-10 in the NA3VC UL Standard series.

Similar Part Numbers

Part Number
NA3VC-16-2-1
NA3VC-16-2-100
NA3VC-16-2-11
NA3VC-16-2-12
NA3VC-16-2-13
NA3VC-16-2-14
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Number Of Cores
(Core)
Logarithm Finished outer diameter
(mm)

SGD 4.98

1 Piece(s) 4 Day(s) or more -11.25162-6.3

SGD 188.01

1 Piece(s)Available 4 Day(s) or more -1001.25162-6.3

SGD 33.94

1 Piece(s) 4 Day(s) or more -111.25162-6.3

SGD 36.18

1 Piece(s) 4 Day(s) or more -121.25162-6.3

SGD 38.43

1 Piece(s) 4 Day(s) or more -131.25162-6.3

SGD 40.68

1 Piece(s) 4 Day(s) or more -141.25162-6.3

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)