(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

KVC36 UL Standard (KVC36-0.2-2P-100)

KVC36 UL Standard KVC36-0.2-2P-100

150 V Cable for UL-AWM Standard Signals

  • c-UL
  • VW-1
  • FT-1
  • ULAWM
  • Oil-Resistant
  • Strand Wire
  • Twisted Pair
  • Less than 100 V

· 1.5P sizes are not twisted pairs.
· This product is compatible with "UL Traceability Program / Processed Wire". (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* Color and softness may vary slightly due to manufacturer changes.

Electrical Appliance and Material Safety Law certificate is not obtained.

PDF

Part Number

Configured Part Number is shown.

KVC36-0.2-2P-100

Specifications

KVC36 UL Standard:Related Image

Model NumberSection Area
(mm2)
Number of Pairs *3
1P = 2 Cores
Total Length
or
Specified Length
Model NumberSection Area
(mm2)
Number of Pairs *3
1P = 2 Cores
Total Length
or
Specified Length
KVC36
(Twisted Pair Type)
0.21P1
~
100
(Specify 1 m
Increment)
1.5P (3-Core)
2P
3P
4P
5P
6P
7P
8P
10P
12P
15P
18P
20P
25P
30P
32P
0.31P
1.5P (3-Core)
2P
3P
4P
5P
6P
7P
8P
10P
12P
15P
18P
20P
25P
30P
32P

More Information


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
*3 Check the indications for number of cores, pair number, core / pair number, and pair number / core when  ordering.

KVC36 UL Standard:Related Image

KVC36 UL Standard:Related Image
KVC36 UL Standard:Related Image

Specifications
Model NumberSection Area
( mm2) *2
Number of Pairs *1
1P = 2 Cores
Total LengthAWG
Estimate* 2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished *5
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecification
Allowable Current
A (30°C)* 3
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Withstand Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *4Thickness
(mm)
Material *4Thickness
(mm)
Material *4
KVC36
(Twisted Pair Type)
0.21P1
~
100
(Specify 1 m
Increment)
25Twisted Pair23.1135113 or less50 or more1500
AC
7/0.180.54Tin0.255PVC1.050.5PVCULAWM2936
c-UL
1.5P (3-Core)33.31640.5
2P45.22740.85ULAWM2576
c-UL
3P65.43540.85
4P85.94030.85
5P106.35030.85
6P127.05530.9
7P147.26030.9
8P167.77030.9
10P208.58520.95
12P248.99520.95
15P309.711520.95
18P3610.513520.95
20P4011.014520.95
25P5012.517520.95
30P6013.520521
32P6413.521521
0.31P2323.720762.3 or less50 or more1500
AC
12/0.180.7N/A0.31.30.55ULAWM2936
c-UL
1.5P (3-Core)34.02560.6
2P45.73560.85ULAWM2576
c-UL
3P66.65051.0
4P87.36551.0
5P108.07541.0
6P128.89041.05
7P148.99541.05
8P169.511041.1
10P2011.014041.15
12P2411.515531.15
15P3012.518531.15
18P3613.522031.2
20P4014.023531.2
25P5015.524531.25
30P6016.534021.25
32P641736021.25


*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*5 For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.      

Current Reduction Factor
Ambient Temperature (°C)30405060708090100
Current Reduction Factor1.000.930.860.770.680.580.450.26
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 5 x 0.93 = 4.65 (A) when the ambient temperature is 40°C at 1P 0.2mm2

KVC36 UL Standard:Related Image

Wire Core Identification Table
Pair No.1234567891011
Insulator ColorBlackBlackRedRedGreenGreenYellowYellowBrownBrownBlueBlueGrayGrayOrangeOrangePurplePurpleLight GreenLight GreenPinkPink
Color of Identification Line-White-White-White-White-White-White-White-White-White-White-White
Pair No.1213141516171819202122
Insulator ColorLight BlueLight BlueWhiteWhiteGreenGreenYellowYellowBrownBrownBlueBlueGrayGrayOrangeOrangePurplePurpleLight GreenLight GreenPinkPink
Color of Identification Line-White-BlackBlackRedBlackRedBlackRedBlackRedBlackRedBlackRedBlackRedBlackRedBlackRed
Pair No.23242526272829303132  
Insulator ColorLight BlueLight BlueRedRedBlackBlackWhiteWhiteBrownBrownBlueBlueGrayGrayOrangeOrangePurplePurpleLight GreenLight Green  
Color of Identification LineBlackRedBlackGreenGreenYellowGreenYellowGreenYellowGreenYellowGreenYellowGreenYellowGreenYellowGreenYellow  

Pair No.1.5
Insulator ColorBlackBlackRed
Color of Identification Line-White-
* Wire core identification for 1.5 number of pairs (3-core strand)
Part Number
KVC36-0.2-2P-100
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipLogarithm Finished outer diameter
(mm)

SGD 236.86

1 Piece(s) Same day 2P5.2

Loading...

  1. 1

Basic Information

Overall Length(m) 100 Conductor Cross Section(mm2) 0.2 AWG size(AWG) 25
Rated Voltage 150V Shield None Properties Oil resistance
Representative Standard UL / CSA(c-UL) Sheath (outer coating) color Black Sheath (outer coating) material PVC
Insulation body materials PVC Power supply/signal Dual use Other properties Pliability

Please check the type/dimensions/specifications of the part KVC36-0.2-2P-100 in the KVC36 UL Standard series.

Similar Part Numbers

Part Number
KVC36-0.2-1P-100
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipLogarithm Finished outer diameter
(mm)

SGD 148.95

1 Piece(s) Same day 1P3.1

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)