NASE Series Wire Core ID for Sensor (NASEU-23-4-58)

NASE Series Wire Core ID for Sensor NASEU-23-4-58

Click this image to zoom it.

Move the mouse over the image to zoom

ULAWM standard compliant cable for UL standard control equipment sensors, with excellent oil resistance and heat resistance. Three types are available: for fixed general wiring, for sputtering, and for movable use.

  • VW-1
  • ULAWM
  • Sensor
  • Strand Wire

● Available in 3 models: Fixed-use general cables, spatter-resistant cables and mobile cables.
● Mobile use cables and fixed use cables are available as UL standard / oil-resistant model respectively.

· Be careful not to confuse specified length and quantity when ordering.
Please note spatter-resistant cables are not UL standard approved.
For use on sensors and weak current circuits.
∙ This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* All unit prices are per meter. 
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter]
* Color and softness may vary slightly due to manufacturer changes.

Electrical Appliance and Material Safety Law certificate has not been obtained.

PDF

Part Number

Configured Part Number is shown.

NASEU-23-4-58

Specifications

NASE Series Wire Core ID for Sensor:Related Image

Model NumberAWG / Conductor
Cross-Sectional Area (mm2)
Number of CoresTotal Length
or
Specified Length
Sample
Provided
NASEU28
* (0.08 mm2)
21
~
100
(Specify 1 m
Increment)
3
4
23
* (0.3mm2)
2
3
4
NA3SEU20
* (0.5mm2)
2
3
4
NASES0.3
* (AWG23)
2
3
4
0.5
* (AWG21)
2
3
4
NA3SER23
* (0.3mm2)
2
3
4
21
* (0.5mm2)
2
3
4
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.

More Information

Sheath ColorNavy
Operating Temperature Range0 ~ 80°C
Standard AcquiredULAWM20276/ULAWM2464
ULAWM2103/ULAWM2517
Bending RadiusFinished Outer Diameter x 6

Current Reduction Factor
Ambient
Temperature (°C)
3040506070
Current
Reduction Factor
1.00.890.780.630.45
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value. If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value for NASEU AWG23 2-core when the ambient temperature is 40°C: 4 x 0.89 = 3.56 (A)

Structure Outline
 NASEUNA3SEUNASESNA3SER
ConductorTin Plated Annealed Copper Stranded Wire
InsulatorVinylFluorine Resin
TwistingTwisted Core
ShieldN/A
SheathVinylHeat-Resistant Spatter-Resistant VinylVinyl

NASE Series Wire Core ID for Sensor:Related Image

Specifications
FeaturesModel NumberAWG / Conductor
Cross-Sectional Area (mm2)
Number
of
Cores
Specified Length
(m)
ConductorInsulation
Thickness
(mm)
Wire Core
Outer Diameter
Approx. (mm)
Sheath
Thickness
(mm)
Finished
Outer Diameter
(mm)
Electrical PropertiesApproximate
Mass
kg/km
SpecificationUseStructure
Strands / mm
Outer Diameter
Approx. / mm
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Test Voltage
V / Min
Allowable Current
A (30 °C)
ULAWM20276
(30 V 80°C)
VW-1 Flame Retardant
For Fixed
(Oil-Resistant /
Soft)
NASEU28
* (0.08 mm2)
21
~
100
(Specify
1 m
Increment)
19/0.080.40.150.70.72.8214 or less1 or more300
AC
111
30.64112
40.55114
23
* (0.3mm2)
227/0.12TA0.720.191.10.9 472 or less5 or more300
AC
420
30.82424
40.67326
ULAWM2464
(300V 80°C)
VW-1 Flame Retardant
NA3SEU20
* (0.5mm2)
246/0.12TA1.000.41.81.2642 or less5 or more500
AC
547
31.06553
40.83555
Standard Not Obtained
(Less than 100 V 80°C)
For Spatter
(Fixed)
NASES0.3
* (AWG23)
260/0.08
High Strength Copper Alloy
Stranded Wire
0.720.21.10.94.082.2 or less1000
or more
500
AC
620
30.8522
40.65525
0.5
* (AWG21)
23/33/0.08
High Strength Copper Alloy
Stranded Wire
1.10.31.71.3650.8 or less1000
or more
1000
AC
941
31.2846
40.9750
ULAWM2103
(300V 105°C)
VW-1 Flame Retardant
For Movable
(Oil-Resistant)
NA3SER23
* (0.3mm2)
23/20/0.080.80.21.20.8469 or less100M
or more
2000
AC
6.321.0
30.75.523.7
40.555.026.1
ULAWM2517
(300V 105°C)
VW-1 Flame Retardant
21
* (0.5mm2)
23/33/0.081.040.281.61.4642.2 or less100M
or more
2000
AC
9.245.1
31.258.049.2
41.057.255.9
* (~ mm2) is to be used only as an estimated section area. Refer to the comparison table on >>Click here for details.
* For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.

NASE Series Wire Core ID for Sensor:Related Image
Part Number
NASEU-23-4-58
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Number Of Cores
(Core)
Finished outer diameter
(mm)
Rated Voltage Properties Representative Standard Insulation body materials Other properties

SGD 88.45

1 Piece(s) 4 Day(s) or more 580.32344[For Low Current Circuits] 30VOil resistanceULPVCPliability

Loading...

  1. 1

Basic Information

Shield None Sheath (outer coating) color Navy color Sheath (outer coating) material PVC

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)