Tube Fitting for Chemicals, Chemical Type, Straight (APC12-04)

Tube Fitting for Chemicals, Chemical Type, Straight APC12-04

Click this image to zoom it.

Move the mouse over the image to zoom

  • Tube Fitting for Chemicals, Chemical Type, Straight
  • Tube Fitting for Chemicals, Chemical Type, Straight
  • On Sale Till 31/03/2025

PPS is used for the main body material for excellent heat resistance, flame retardancy, and chemical resistance.

[Features]
· The main body uses PPS resin having superior heat resistance, flame retardant (UL94V-0) and chemical resistance properties.
· Has option for using FKM in the seal area. Other options include NBR and EPDM.
· No need to worry about rust or metal ions.
· Selectable from two packaging specifications--normal packaging and clean room packaging--according to the specific application.

PDF

Japanese Only

Specifications Of Chemical Type Tube Fitting For Chemicals - Straight

Chemical Type Tube Fitting - Straight: related image

Appearance of Chemical Type Tube Fitting For Chemicals - Straight

Chemical Type Tube Fitting - Straight: related image

Dimensional drawing

Usable FluidsAir, water (see conditions*), other (see conditions*)
Maximum Operating Pressure0.9 MPa (at 0 to 20°C)
Operating Vacuum Pressure-100 kPa
Operating Temperature Range0 to 80°C (when NBR sealing rubber is used: 0 to 60°C) (no freezing)
  • *1. When the fluid used is water or other chemicals, the following conditions must be observed.
  1. 1. When using water or other liquids, make sure the surge pressure stays below the maximum operating pressure.
  2. 2. Be sure to use an insert ring when using water or other liquids.
  3. 3. For chemicals, mixed gases, etc., compliance with the specifications may vary depending on usage conditions, so please check before using.

Formats

FormatTube Outer Diameter
φD
RABLTube End
C
Hex
H1
Hex
H2
φPEffective Cross-Sectional Area
(mm2)
Mass
(g)
CAD
File Name
APC4-01 (4) (5) (6)4R1/8827.923.918.9102.510.54.52.3APC4-01
APC6-01 (4) (5) (6)6R1/8830.326.321.312412.5112.9APC6-01
APC6-02 (4) (5) (6)R1/41133.327.2144.4APC6-02
APC6-03 (4) (5) (6)R3/81230.42420.8176.5APC6-03
APC8-01 (4) (5) (6)8R1/8832.328.322.814414.5113.8APC8-01
APC8-02 (4) (5) (6)R1/41135.329.26234.5APC8-02
APC8-03 (4) (5) (6)R3/81231.42522.3176.2APC8-03
APC10-02 (4) (5) (6)10R1/41137.531.525.317617.8236.4APC10-02
APC10-03 (4) (5) (6)R3/81238.532.28407.3APC10-03
APC12-02 (4) (5) (6)12R1/41141.435.428.419622239.6APC12-02
APC12-03 (4) (5) (6)R3/81242.436.184011APC12-03
APC12-04 (4) (5) (6)R1/21538.430.222105513APC12-04

Units: mm

  • *L dimensions are reference dimensions after tightening with screws.
  • *For (4) in the order format, input -E (EPDM) or -N (NBR) only if you want to change the sealing rubber material.
  • *For (5) in the order format, input -TP if you want the sealing tape specification.
  • *For (6) in the order format, input -C if you want the clean room packaging specification.
Part Number
APC12-04
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipApplicable Fluid Application Seal Material Operating Temperature
(°C)
Applicable Tube O.D.1
(φ)
Nominal of Thread 1 Package Specifications Thread Part Seal Specification

SGD 9.96

1 Piece(s) 9 Day(s) Water / Air / Chemicals、Solvent / Mixed GasFoods・Drug-Related / Heat Resistant[Fluororubber] FKM0~80121/2Regular Packaging SpecificationsStandard Specifications

Loading...

  1. 1

Basic Information

Types One-Touch Couplings Fitting Type Screw Mount Direction Body Material PPS Resin
Thread Material PPS Resin Screw Mounting, Direction Straight Connection Screw Type 1 R

Please check the type/dimensions/specifications of the part APC12-04 in the Tube Fitting for Chemicals, Chemical Type, Straight series.

Similar Part Numbers

Part Number
APC10-02E
APC10-02EC
APC10-02N
APC12-04-TP
APC12-04C
APC12-04E
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipApplicable Fluid Application Seal Material Operating Temperature
(°C)
Applicable Tube O.D.1
(φ)
Nominal of Thread 1 Package Specifications Thread Part Seal Specification

SGD 5.91

1 Piece(s) 8 Day(s) or more Mixed Gas / Water / Air / Chemicals、SolventFoods・Drug-Related / Heat ResistantEPDM0~80101/4Regular Packaging SpecificationsStandard Specifications

SGD 6.59

1 Piece(s) 9 Day(s) or more Mixed Gas / Water / Air / Chemicals、SolventClean circumstance / Foods・Drug-Related / Heat ResistantEPDM0~80101/4Clean Room Packaging SpecificationsStandard Specifications

SGD 5.91

1 Piece(s) 8 Day(s) or more Water / AirFoods・Drug-Related[Standard (NBR Nitrile Rubber )] NBR0~60101/4Regular Packaging SpecificationsStandard Specifications

SGD 10.50

1 Piece(s) 10 Day(s) or more Mixed Gas / Water / Air / Chemicals、SolventFoods・Drug-Related / Heat Resistant[Fluororubber] FKM0~80121/2Regular Packaging SpecificationsSealing Tape Specifications

SGD 10.12

1 Piece(s) 9 Day(s) or more Mixed Gas / Water / Air / Chemicals、SolventClean circumstance / Foods・Drug-Related / Heat Resistant[Fluororubber] FKM0~80121/2Clean Room Packaging SpecificationsStandard Specifications

SGD 6.59

1 Piece(s) 8 Day(s) or more Mixed Gas / Water / Air / Chemicals、SolventFoods・Drug-Related / Heat ResistantEPDM0~80121/2Regular Packaging SpecificationsStandard Specifications

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)