(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Control Equipment Standard Electromagnetic Valve 112 Series Vacuum Compatible (Part Numbers)

Control Equipment Standard Electromagnetic Valve 112 Series Vacuum Compatible

Lightweight, compact, 2- /3-port direct acting electromagnetic vacuum valve.
[Features]
·A series of vacuum and positive pressure combined types that enables forced release or vacuum break is available as well
·With full of various functions of 2- / 3-port valves by adopting an external pilot method
·It demonstrates versatility in spite of its compact body
·NC (normally closed) / NO (normally open) shared 2- / 3-port valve that is not restricted by piping port position and flow direction
·It can be used not only in vacuum but also in combination with positive pressure, and can be used as a valve for vacuum break and forced release
[Applications]
・ Compatible with pneumatic equipment and production lines in all industries

(i)Caution

  • Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
    There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details.

PDF

Part Number

Configured Part Number is shown.

V112E1-2 DC24V

Drawing

Dimensional drawing of 112E1 and V112E1

Dimensional drawing of 112E1 and V112E1

Product Specifications

ItemsBasic FormFor positive pressureFor vacuum
Direct piping / F, FE type manifold112E1V112E1
A type manifoldA112E1AV112E1
Operating fluidAir
Operating methodExternal pilot type
Flow characteristicsSonic conductance C dm^3 / (s · bar)^Note 10.84
Effective cross-sectional area [Cv value] mm^24.2 [0.23]
Piping connection diameter^Note 2MainM5 × 0.8
PilotM5 × 0.8
LubricationNot required
Operating pressure range (MPa)Main0 to 0.7-100 kPa to 0.15
Pilot0.2 to 0.7
Guaranteed pressure resistance MPa1.05
Response time
ON/OFF ms
12 V DC, 24 V DC15 or less / 25 or less
100 V AC, 200 V AC15 or less / 15 or less
Maximum operating frequency: Hz5
Operating temperature range (ambient and operating fluid) °C+5 to +50
Impact resistance m/s^21,373.0 (Axial direction 294.2)
Mounting DirectionFree

*1: The value of sonic conductance is a calculated value, not an actual measurement value
Note 2: Value at air pressure 0.5 MPa

Electrical specifications

ItemsRated voltage
12 V DC24 V DC100 V AC200 V AC
MethodBuilt-in fly-wheel diode for surge preventionShading method
Operating Voltage Range: V10.8 to 13.2
(12±10%)
21.6 to 26.4
(24±10%)
90 to 132
[100 (-10 to +32)%]
180 to 264
[200 (-10 to +32)%]
Current
(When rated voltage is applied)
Frequency Hz50605060
Starting mA (r.m.s)36321816
Excitation mA (r.m.s)130 (1.6W)
[140 (1.7 W) for the type with LED indicator]
65 (1.6W)
[75 (1.8 W) for the type with LED indicator]
24201210
Allowable circuit leakage current value mA8442
Insulation resistance MΩ100 or More
Connection method and lead lengthStandardGrommet type: 300 mm
OptionPlug connector type: 300 mm
Lead Wire ColorBrown (+)
Black (-)
Red (+)
Black (-)
YellowWhite
LED indicator (optional) colorRedYellowGreen
Surge Protection (Standard Equipment)Fly-Wheel DiodeVaristor

Solenoid valve weight

Basic FormWeight
112E180
A112E185
V112E180
AV112E185

Manifold weight

Manifold TypeWeight calculation formula for each serial number
(n = serial number)
Block plate
112M□F(20 × n) +306
112M□FE(40 × n) +5011
112M□A(60 × n) +6011

Usage examples

Usage example of 112 series

Product features details

It demonstrates versatility in spite of its compact body

For positive pressure, stable switching from low pressure to high pressure (0 to 0.7 MPa) is possible.
It can also be used as a selector valve (2-pressure switching valve) or divider valve (distribution valve).

Property Performance Information / Test Information

Flow rate: How to read the figure (When the supply pressure is 0.5 MPa and the flow rate is 210 L/min (ANR), the valve outlet pressure is 0.4 MPa)

Flow rate: How to read the figure (When the supply pressure is 0.5 MPa and the flow rate is 210 L/min (ANR), the valve outlet pressure is 0.4 MPa)

Development story

 

This is a product developed through rigorous testing by combining the design know-how and manufacturing technology that have been cultivated since its founding in order to meet the customers' needs.

Part Number
V112E1-2 DC24V
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipNumber of Ports Voltage Wiring Lead wire length
(mm)
Manual button

SGD 83.39

1 Piece(s) 11 Day(s) or more 2-port valveDC24VGrommet Type-Non-locking type

Loading...

  1. 1
 

Basic Information

Type Electromagnetic Vacuum Valve Application Single Item Operating Mounting Orientation Direct
Solenoid Type Single Switching Type 2-position Normally Closed Driving Type External pilot type
Effective Sectional Area(mm2) 4.2 Pipe Port Type M Plumbing Thread Nominal M5
Seal Type Elastic Seal Sonic Speed Conductance 0.84 CV Value 0.23
Specifications Standard

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)