Long Size Proximity Sensor [E2E2]

Long Size Proximity Sensor [E2E2]
  • On Sale Till 31/03/2025

[Features]
· Proximity sensor with long thread length.
· To make cord protector a standard equipment, together with increasing the tightening strength.
· Increase the visibility of indicator lights and adopt for all models the milling cut for spanner grasping.

PDF

Japanese Only

Dimensional Drawing of OMRON Proximity Sensors

OMRON Proximity Sensors Shielded Type

Long size proximity sensor E2E2 shielded type outline drawing

OMRON Proximity Sensors Non-shielded type

Long size proximity sensor E2E2 non-shielded type outline drawing

Specification Table of OMRON Proximity Sensors

OMRON Proximity Sensors Ratings/Performance

Proximity Sensors DC 2-wire type (E2E2-X□D□)

Proximity Sensors itemProximity Sensors format
Model E2E2-X3D□Model E2E2-X8MD□Model E2E2-X7D□Model E2E2-X14MD□Model E2E2-X10D□Model E2E2-X20MD□
Proximity Sensors sizeM12M18M30
shieldshieldUnshieldedshieldUnshieldedshieldUnshielded
Detection distance3mm±10%8mm±10%7mm±10%14mm±10%10mm±10%20mm±10%
Set distance *10 to 2.4 mm0 to 6.4 mm0 to 5.6 mm0 to 11.2 mm0 to 8 mm0 to 16 mm
Hysteresis10% or less of the detection distance
Detected objectMagnetic metals (non-magnetic metals will reduce the detection distance. See page 5 of the digital catalog for "Characteristics Data")
Standard detection objectIron 12 x 12 x 1 mmIron 30×30×1mmIron 18 x 18 x 1 mmIron 30×30×1mmIron 30×30×1mmIron 54×54×1mm
Response frequency *21kHz800Hz500Hz400Hz100Hz
Power supply voltage
(operating voltage range)
DC12-24V ripple (pp) 10% or less (DC10-30V)
Leakage current0.8mA or less
Control OutputOpening and closing capacity3 to 100mA
Residual voltage3V or less (load current 100mA, cord length 2m)
Indicator LightD1 type: Operation indicator (red), setting indicator (green)
D2 type: Operation indicator (red)
Operation mode
(when detecting object approaching)
D1 type: NO, D2 type: NC
For details, refer to the "Input/Output stage circuit diagram" time chart → Digital catalog page 8
Protection CircuitSurge absorption, load short circuit protection
Ambient temperatureDuring operation and storage: -25 to +70°C (but do not freeze or condense)
Ambient HumidityDuring operation and storage: 35 to 95% RH (but no condensation)
Temperature effectsWithin ±10% of detection distance at +23°C within the temperature range of -25 to +70°C
Voltage EffectsWithin ±1% of detection distance at rated power supply voltage, within ±15% of rated power supply voltage
Insulation Resistance50MΩ or more (DC500V megger) between live parts and case
Withstand voltageAC1,000V 50/60Hz 1min Between live parts and case
Vibration (durability)10 to 55Hz, double amplitude 1.5mm, 2h each in X, Y, and Z directions
Impact (durability)1,000m/s2 10 times each in X, Y, and Z directions
Protective structureIEC standard IP67, Omron in-house standard oil resistance
Connection methodCord pull-out type (standard cord length 2m)
Weight (packaged)Approx. 65gApprox. 150gApprox. 210g
Proximity Sensors Materialcasebrass
Detection surfacePolybutylene terephthalate (PBT)
Clamping NutBrass, nickel plated
Toothed washerIron, zinc plated
accessoriesoperating instructions

*1.The Proximity Sensors Use within the range where the green indicator light is on. (Excluding D2 type)
*2.The response frequency of the DC switching unit is the average value. The measurement conditions are as follows: The Proximity Sensors standard sensing object is used, the interval between sensing objects is twice that of the standardsensing object, and the set distance is 1/2 the sensing distance.

Proximity Sensors DC 3-wire type (E2E2-X□C□)

Proximity Sensors itemProximity Sensors format
Model E2E2-X2C□Model E2E2-X5MC□Model E2E2-X5C□Model E2E2-X10MC□Model E2E2-X10C□Model E2E2-X18MC□
Proximity Sensors sizeM12M18M30
shieldshieldUnshieldedshieldUnshieldedshieldUnshielded
Detection distance2mm±10%5mm±10%5mm±10%10mm±10%10mm±10%18mm±10%
Set distance0 to 1.6 mm0 to 4 mm0 to 4 mm0 to 8 mm0 to 8 mm0 to 14 mm
Hysteresis10% or less of the detection distance
Detected objectMagnetic metals (non-magnetic metals will reduce the detection distance. See page 5 of the digital catalog for "Characteristics Data")
Standard detection objectIron 12 x 12 x 1 mmIron 15 x 15 x 1 mmIron 18 x 18 x 1 mmIron 30×30×1mmIron 30×30×1mmIron 54×54×1mm
Response frequency *11.5kHz400Hz600Hz200Hz400Hz100Hz
Power supply voltage
(operating voltage range)*2
DC12-24V ripple (pp) 10% or less (DC10-30V)
Current consumption13mA or less
Proximity Sensors Control OutputOpening and closing capacityNPN open collector output 200mA or less (DC30V or less)
Residual voltage2V or less (load current 200mA, cord length 2m)
Indicator LightOperation indicator: (red)
Proximity Sensors Operation mode
(when detecting object approaching)
C1 type: NO, C2 type: NC
For details, refer to the "Input/Output stage circuit diagram" time chart → Digital catalog page 8
Protection CircuitReverse connection protection, surge absorption, load short circuit protection
Ambient temperatureDuring operation and storage: -40 to +85°C (but no freezing or condensation)
Ambient HumidityDuring operation and storage: 35 to 95% RH (but no condensation)
Temperature effectsWithin ±15% of detection distance at +23°C in a temperature range of -40 to +85°C
Within ±10% of detection distance at +23°C in a temperature range of -25 to +70°C
Voltage EffectsWithin ±1% of detection distance at rated power supply voltage, within ±15% of rated power supply voltage
Insulation Resistance50MΩ or more (DC500V megger) between live parts and case
Withstand voltageAC1,000V 50/60Hz 1min Between live parts and case
Vibration (durability)10 to 55Hz, double amplitude 1.5mm, 2h each in X, Y, and Z directions
Impact (durability)1,000m/s2 10 times each in X, Y, and Z directions
Protective structureIEC standard IP67, Omron in-house standard oil resistance
Proximity Sensors Connection methodCord pull-out type (standard cord length 2m)
Weight (packaged)Approx. 75gApprox. 160gApprox. 220g
Proximity Sensors Materialcasebrass
Detection surfacePolybutylene terephthalate (PBT)
Clamping NutBrass, nickel plated
Toothed washerIron, zinc plated
accessoriesoperating instructions

*1.The response frequency of the DC switching unit is the average value. Measurement conditions are as follows: The Proximity Sensors standard detection object is used, the interval between detection objects is twice that of the standarddetection object, and the set distance is 1/2 the detection distance.
*2.The Proximity Sensors Can be used with a non-smooth full-wave rectified power supply of DC24V±20% (average value).

Proximity Sensors AC 2-wire type (E2E2-X□Y□)

Proximity Sensors itemProximity Sensors format
Model E2E2-X2Y□Model E2E2-X5MY□Model E2E2-X5Y□Model E2E2-X10MY□Model E2E2-X10Y□Model E2E2-X18MY□
Proximity Sensors sizeM12M18M30
shieldshieldUnshieldedshieldUnshieldedshieldUnshielded
Detection distance2mm±10%5mm±10%5mm±10%10mm±10%10mm±10%18mm±10%
Set distance0 to 1.6 mm0 to 4 mm0 to 4 mm0 to 8 mm0 to 8 mm0 to 14 mm
Hysteresis10% or less of the detection distance
Detected objectMagnetic metals (non-magnetic metals will reduce the detection distance. See page 5 of the digital catalog for "Characteristics Data")
Standard detection objectIron 12 x 12 x 1 mmIron 15 x 15 x 1 mmIron 18 x 18 x 1 mmIron 30×30×1mmIron 30×30×1mmIron 54×54×1mm
Response Frequency25Hz
Power supply voltage
(operating voltage range) *1
AC24~240V (AC20~264V) 50/60Hz
Leakage current1.7mA or less
Proximity Sensors Control OutputOpening and closing capacity *25 to 200mA5 to 300mA
Residual voltageCharacteristics data → See page 5 of the digital catalog
Indicator LightOperation indicator: (red)
Operation mode
(when detecting object approaching)
Y1 type: NO, Y2 type: NC
For details, refer to the "Input/Output stage circuit diagram" time chart → Digital catalog page 8
Ambient temperature *1, 2During operation and storage: -40 to +85°C (but no freezing or condensation)
Ambient HumidityDuring operation and storage: 35 to 95% RH (but no condensation)
Temperature effectsWithin ±15% of detection distance at +23°C in a temperature range of -40 to +85°C
Within ±10% of detection distance at +23°C in a temperature range of -25 to +70°C
Voltage EffectsWithin ±1% of detection distance at rated power supply voltage, within ±15% of rated power supply voltage
Insulation Resistance50MΩ or more (DC500V megger) between live parts and case
Withstand voltageAC4,000V 50/60Hz 1min Between live parts and case
Vibration (durability)10 to 55Hz, double amplitude 1.5mm, 2h each in X, Y, and Z directions
Impact (durability)1,000m/s2 10 times each in X, Y, and Z directions
Protective structureIEC standard IP67, Omron in-house standard oil resistance
Proximity Sensors Connection methodCord pull-out type (standard cord length 2m)
Weight (packaged)Approx. 65gApprox. 150gApprox. 210g
Proximity Sensors Materialcasebrass
Detection surfacePolybutylene terephthalate (PBT)
Clamping NutBrass, nickel plated
Toothed washerIron, zinc plated
accessoriesoperating instructions

*1.When Proximity Sensors using 24V AC, use within the ambient temperature range of -25 to +85°C.
*2.When using M18 and M30 types in ambient temperatures between 70°C and 85°C, use a control output (switching capacity) in the range of 5 to 200mA.

Part Number
E2E2-X2C1 2M
E2E2-X2Y1 2M
E2E2-X3D1 2M
E2E2-X5MC1 2M
E2E2-X5Y1 2M
E2E2-X5Y1 5M
E2E2-X8MD1 2M
E2E2-X10MY1 2M
E2E2-X10Y1 2M
E2E2-X18MY1 2M
E2E2-X18MY2 2M
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipDetection distance L1 [classification]
(mm)
Operating Environment Shielded / Non-shielded Screw Detection Head Size Head size Depth (range)
(mm)
Head size Depth
(mm)
Acquired Standards Types Power Type Power Supply Voltage Output Mode Operation Mode Connector pin arrangement Cable Length
(m)
Different Frequency Type Cable Specifications Included functions Combination amplifier/head Detection distance L1 details
(mm)

SGD 70.91

SGD 14.18

1 Piece(s) Same day ~2Standard / Oil Resistance Reinforcement / Cold ResistanceShield TypeM1250.1~6055CE / IECThread Length Long Size, DC, 3-LineDirect Current 3-Wire Type12-24 VDCNPN Open CollectorNO-2StandardVinyl (PVC)-insulated round cord, φ4, 2-core/3-core--2

SGD 109.01

1 Piece(s) 4 Day(s) or more ~2Standard / Oil Resistance Reinforcement / Cold ResistanceShield TypeM1250.1~6055CE / IEC / CCCThread Length Long Size, AC, 2-LineAC, 2-Wire24-240 VACAC, 2-WireNO-2StandardVinyl (PVC)-insulated round cord, φ4, 2-core/3-core--2

SGD 106.24

SGD 21.25

1 Piece(s) Same day ~3Standard / Oil Resistance Reinforcement / Cold ResistanceShield TypeM1250.1~6055CE / IECThread Length Long Size, DC, 2-LineDirect Current 2-Wire Type12-24 VDCDC 2-wire polarizedNO-2StandardVinyl (PVC)-insulated round cord, φ4, 2-core/3-core--3

SGD 70.66

SGD 14.13

1 Piece(s) Same day ~5Standard / Oil Resistance Reinforcement / Cold ResistanceNon Shield TypeM1250.1~6055CE / IECThread Length Long Size, DC 3-WireDirect Current 3-Wire Type12-24 VDCNPN Open CollectorNO-2StandardVinyl (PVC)-insulated round cord, φ4, 2-core/3-core--5

SGD 129.47

1 Piece(s) 4 Day(s) or more ~5Standard / Oil Resistance Reinforcement / Cold ResistanceShield TypeM1850.1~6060CE / IEC / CCCThread Length Long Size, AC, 2-LineAC, 2-Wire24-240 VACAC, 2-WireNO-2StandardVinyl (PVC)-insulated round cord, φ6, 2-core/3-core--5

SGD 131.89

1 Piece(s) 4 Day(s) or more ~5Standard / Oil Resistance Reinforcement / Cold ResistanceShield TypeM1850.1~6060CE / IEC / CCCThread length long size, AC, 2-LineAC, 2-Wire24-240 VACAC, 2-WireNO-5StandardVinyl (PVC)-insulated round cord, φ6, 2-core/3-core--5

SGD 88.80

SGD 17.76

1 Piece(s) Same day ~10Standard / Oil Resistance Reinforcement / Cold ResistanceNon Shield TypeM1250.1~6055CE / IECThread Length Long Size, DC, 2-LineDirect Current 2-Wire Type12-24 VDCDC 2-wire polarizedNO-2StandardVinyl (PVC)-insulated round cord, φ4, 2-core/3-core--8

SGD 101.58

1 Piece(s) 4 Day(s) or more ~10Standard / Oil Resistance Reinforcement / Cold ResistanceNon Shield TypeM1850.1~6060CE / IEC / CCCThread Length Long Size, AC, 2-LineAC, 2-Wire24-240 VACAC, 2-WireNO-2StandardVinyl (PVC)-insulated round cord, φ6, 2-core/3-core--10

SGD 130.68

1 Piece(s) 4 Day(s) or more ~10Standard / Oil Resistance Reinforcement / Cold ResistanceShield TypeM3060.1~7065CE / IEC / CCCThread Length Long Size, AC, 2-LineAC, 2-Wire24-240 VACAC, 2-WireNO-2StandardVinyl (PVC)-insulated round cord, φ6, 2-core/3-core--10

SGD 131.89

1 Piece(s) 4 Day(s) or more ~20Standard / Oil Resistance Reinforcement / Cold ResistanceNon Shield TypeM3060.1~7065CE / IEC / CCCThread length long size, AC, 2-LineAC, 2-Wire24-240 VACAC, 2-WireNO-2StandardVinyl (PVC)-insulated round cord, φ6, 2-core/3-core--18

SGD 138.27

1 Piece(s) 49 Day(s) or more ~20Standard / Oil Resistance ReinforcementNon Shield TypeM3060.1~7065CE / IEC-AC, 2-Wire24-240 VACAC, 2-WireNC-2-Vinyl (PVC)-insulated round cord, φ6, 2-core/3-core--18

Loading...

  1. 1
 

Basic Information

Shape Screw Type Detected Objects Magnetic Metal Detection Direction Front Surface
Case Material Brass Detecting Surface Material Polybutylene Terephthalate Amplifier Amplifier Built-in Type
Protection Structure (IEC) IP67 Connection Method Pre-wired model