(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Capacitive Proximity Sensor for Liquid Level Detection [E2K-L]

Capacitive Proximity Sensor for Liquid Level Detection [E2K-L]

[Features]
· Liquid level sensor is not affected by color of pipe liquid.
· Bypass pipe mounting type.
· It corresponds to a wide pipe diameter of ø8 to 11 mm, ø12 to 26 mm.
· Built-in amplifier type, space-saving.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

Dimensional Drawing of OMRON Proximity Sensors

E2K-L13MC□
Capacitive proximity sensor for detecting liquid level [E2K-L] E2K-L13MC□ Dimensions
E2K-L26MC□
Capacitive proximity sensor for detecting liquid level [E2K-L] E2K-L26MC□ Dimensions

Specification Table of OMRON Proximity Sensors

■ Proximity Sensors Ratings/Performance

Proximity Sensors ItemFormat of Proximity Sensors
Proximity Sensors Model E2K-L13MC□Proximity Sensors Model E2K-L26MC□
Applicable PipeMaterialNon-metallic
sizeOutside diameterφ8~11mmφ12~26mm
Wall thicknessLess than 1mm1.5mm or less
Detectable Objectsliquid*
Repeated distance accuracy±0.2mm or less
Hysteresis
(Reference value as it varies depending on the tube size and solution)
0.6 to 5 mm0.3 to 3 mm
Power supply voltage (operating voltage)DC12-24V ripple 10% or less (DC10.8-30V)
Current consumption12mA or less
Control OutputOpening and closing capacity100mA or less
Residual voltage1V or less (load current: 100mA, cord length: 2m)
Detection liquid level positionFor details, refer to the Proximity Sensor Technical Guide Operation.
Indicator LightDetection indicator (orange)
Ambient Temperature RangeOperating temperature: 0 to +55°C, Storage temperature: -10 to +65°C (nofreezing or condensation)
Ambient Humidity RangeDuring use and storage: 25 to 85% RH (no condensation)
Temperature effectsDetection level ±4 mm at +23°C within the temperature range of 0 to +55°C(pure water and 20% salt water)
(However, for E2K-L13MC□ with pure water and a pipe diameter of φ8, ±6 mm)
Voltage EffectsWithin the range of rated power supply voltage ±10%, detection level atrated power supply voltage ±0.5mm
Insulation resistance50MΩ or more (DC500V megger) between live parts and case
Withstand voltageAC500V 50/60Hz 1min Between live parts and case
Vibration (durability)10 to 55Hz, double amplitude 1.5mm, 2h each in X, Y, and Z directions
Impact (durability)500m/s 2  3 times each in X, Y, and Z directions
Protective structureIEC standard IP66
Connection methodCord pull-out type (standard cord length 2m)
Weight (packaged)Approx. 70g
MaterialCases, CoversHeat-resistant ABS
Cord clampNBR
accessories2 cable ties, 4 anti-slip tubes, instruction manual

*Please check the detection performance of Proximity Sensors with the deviceto be installed before use, as stable detection may not be possible in the following cases.
(1) Proximity Sensors, If the liquid has a low dielectric constantor conductivity, the device may not be able to detect the liquid level because it is a capacitance type.
(2) Proximity Sensors, If the liquid volume is small, or the pipesize is thin and thick, resulting in a small change in capacitance in response to a change in the liquid level.
(3) Proximity Sensors, If there is a high-viscosity liquid film or a large amount of bubbles remainingon the inner wall of the pipe, or if dirt has adhered or accumulated on the inner and outer walls of the pipe.

Part Number
E2K-L13MC1 2M
E2K-L26MC1 2M
E2K-L26MC2 2M
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipDetection distance L1 [classification]
(mm)
Operating Environment Head size Depth (range)
(mm)
Head size Depth
(mm)
The size and width of detection head (range)
(mm)
The size and width of detection head
(mm)
The size and height of detection head (range)
(mm)
The size and height of detection head
(mm)
Types Operation Mode Connector pin arrangement Different Frequency Type Included functions Combination amplifier/head Detection distance L1 details
(mm)

SGD 304.92

1 Piece(s) 4 Day(s) or more ~20Standard / Cold Resistance10~202020.1~302440.1~43Applicable pipe diameter φ8–11 mm/wall thickness of 1 mm or lessNO-StandardBinding bands 2 pcs., non-slip tube 4 pcs.-13

SGD 291.61

1 Piece(s) 4 Day(s) or more ~50Standard / Cold Resistance10~202030.1~403330.1~4034Applicable pipe diameter φ12 - 26 mm/wall thickness of 1.5 mm or lessNO-StandardBinding bands 2 pcs., non-slip tube 4 pcs.-26

SGD 300.60

1 Piece(s) 19 Day(s) or more ~50Standard------Applicable pipe diameter φ12–26 mm/wall thickness of 1.5 mm or lessNC----26

Loading...

  1. 1
 

Basic Information

Shape Groove type Detected Objects Non-magnetic Metal / Conductor and dielectric Shielded / Non-shielded Non Shield Type
Detection Direction Side surface Case Material Heat Resistant ABS Detecting Surface Material Heat Resistant ABS
Amplifier Amplifier Built-in Type Acquired Standards CE / IEC Protection Structure (IEC) IP66
Power Type Direct Current 3-Wire Type Power Supply Voltage 12-24 VDC Output Mode NPN Open Collector
Connection Method Pre-wired model Cable Length(m) 2 Cable Specifications Vinyl (PVC)-insulated round cord, φ2.9, 3-core

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)