Air Operating Ball Valve 3-Port Valve

Air Operating Ball Valve 3-Port Valve

[Brand]CKD
[Material]
Body: Bronze / stainless steel / stainless steel oil-free specifications
[Structure]
Standard bore

Compact air-operated ball valve 3-port valve that covers various fluids such as water, hot water, air, and oil.
[Features]
·Uses an air-driven double piston system that uses a rack and pinion. Valve with reliable operation and high reliability
·Completely air-operated structure allows safe use even in explosive atmosphere
·Can be used outdoors (Excluding those with a solenoid valve for switching)
·Since it rotates in the forward and reverse directions, even if contaminants are mixed in, they can be easily removed
[Applications]
·Can also be used in an explosive atmosphere (Excluding those with a solenoid valve for switching)
·Uses a structure and material that are resistant to scale and water stains

PDF

Japanese Only

Part Number

Configured Part Number is shown.

Part Number
CHG-15
CHG-15
CHG-15-[H,​V,​W]
CHG-15-[E,​N]
CHG-15-[E,​N]-[H,​V,​W]
CHG-15-E
CHG-20
CHG-20-[H,​V,​W]
CHG-20-[E,​N]
CHG-20-[E,​N]-[H,​V,​W]
CHG-25
CHG-25
CHG-25-[H,​V,​W]
CHG-25-[E,​N]
CHG-25-[E,​N]-[H,​V,​W]
CHG-32
CHG-32-[H,​V,​W]
CHG-32-[E,​N]
CHG-32-[E,​N]-[H,​V,​W]
CHG-40
CHG-40-[H,​V,​W]
CHG-40-[E,​N]
CHG-40-[E,​N]-[H,​V,​W]
CHG-50
CHG-50
CHG-50-[H,​V,​W]
CHG-50-[E,​N]
CHG-50-[E,​N]-[H,​V,​W]
CHG-R1-15
CHG-R1-15-[H,​V,​W]
CHG-R1-15-[E,​N]
CHG-R1-15-[E,​N]-[H,​V,​W]
CHG-R1-20
CHG-R1-20-[H,​V,​W]
CHG-R1-20-[E,​N]
CHG-R1-20-[E,​N]-[H,​V,​W]
CHG-R1-25
CHG-R1-25-[H,​V,​W]
CHG-R1-25-[E,​N]
CHG-R1-25-[E,​N]-[H,​V,​W]
CHG-R1-32
CHG-R1-32-[H,​V,​W]
CHG-R1-32-[E,​N]
CHG-R1-32-[E,​N]-[H,​V,​W]
CHG-R1-40
CHG-R1-40-[E,​N]
CHG-R1-50
CHG-R1-50-[E,​N]
CHG-R2-15
CHG-R2-15-[H,​V,​W]
CHG-R2-15-[E,​N]
CHG-R2-15-[E,​N]-[H,​V,​W]
CHG-R2-20
CHG-R2-20-[H,​V,​W]
CHG-R2-20-[E,​N]
CHG-R2-20-[E,​N]-[H,​V,​W]
CHG-R2-25
CHG-R2-25-[H,​V,​W]
CHG-R2-25-[E,​N]
CHG-R2-25-[E,​N]-[H,​V,​W]
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipMaterial Supply Side, Plumbing Thread Nominal Control Side, Plumbing Thread Nominal Port Shape Operating Temperature Range
(°C)
Operating Pressure Range
(MPa)
Actuator Body Material Limit Switch Body Material Limit Switch

SGD 294.46

1 Piece(s) 9 Day(s) or more -1/2B1/2B-0~ 800~ 1.0Double-acting operation type (standard)Bronze (standard)Without switch (standard)--

-

1 Piece(s) 11 Day(s) or more Bronze1/2B1/2BT Port0~800~1.0Double Acting Operation Type---With no switch

-

1 Piece(s) 11 Day(s) or more Bronze1/2B1/2BT Port0~800~1.0Double Acting Operation Type---With 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 11 Day(s) or more Stainless Steel1/2B1/2BT Port0~800~1.0Double Acting Operation Type--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith no switch

-

1 Piece(s) 11 Day(s) or more Stainless Steel1/2B1/2BT Port0~800~1.0Double Acting Operation Type--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith 2 Switches / A-C flow path detection / B-C Flow Path Detection

SGD 485.19

1 Piece(s) 12 Day(s) or more -1/2B1/2B-0~ 800~ 1.0Double-acting operation type (standard)E: Stainless steelWithout switch (standard)--

-

1 Piece(s) 11 Day(s) or more Bronze3/4B3/4BT Port0~800~1.0Double Acting Operation Type---With no switch

-

1 Piece(s) 11 Day(s) or more Bronze3/4B3/4BT Port0~800~1.0Double Acting Operation Type---With 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 11 Day(s) or more Stainless Steel3/4B3/4BT Port0~800~1.0Double Acting Operation Type--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith no switch

-

1 Piece(s) 11 Day(s) or more Stainless Steel3/4B3/4BT Port0~800~1.0Double Acting Operation Type--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith 2 Switches / A-C flow path detection / B-C Flow Path Detection

SGD 338.48

1 Piece(s) 9 Day(s) or more -1B1B-0~ 800~ 1.0Double-acting operation type (standard)Bronze (standard)Without switch (standard)--

-

1 Piece(s) 11 Day(s) or more Bronze1B1BT Port0~800~1.0Double Acting Operation Type---With no switch

-

1 Piece(s) 11 Day(s) or more Bronze1B1BT Port0~800~1.0Double Acting Operation Type---With 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 11 Day(s) or more Stainless Steel1B1BT Port0~800~1.0Double Acting Operation Type--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith no switch

-

1 Piece(s) 11 Day(s) or more Stainless Steel1B1BT Port0~800~1.0Double Acting Operation Type--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 12 Day(s) or more Bronze1 1/4B1 1/4BT Port0~800~1.0Double Acting Operation Type---With no switch

-

1 Piece(s) 12 Day(s) or more Bronze1 1/4B1 1/4BT Port0~800~1.0Double Acting Operation Type---With 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 12 Day(s) or more Stainless Steel1 1/4B1 1/4BT Port0~800~1.0Double Acting Operation Type--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith no switch

-

1 Piece(s) 12 Day(s) or more Stainless Steel1 1/4B1 1/4BT Port0~800~1.0Double Acting Operation Type--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 12 Day(s) or more Bronze1 1/2B1 1/2BT Port0~800~1.0Double Acting Operation Type---With no switch

-

1 Piece(s) 12 Day(s) or more Bronze1 1/2B1 1/2BT Port0~800~1.0Double Acting Operation Type---With 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 12 Day(s) or more Stainless Steel1 1/2B1 1/2BT Port0~800~1.0Double Acting Operation Type--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith no switch

-

1 Piece(s) 12 Day(s) or more Stainless Steel1 1/2B1 1/2BT Port0~800~1.0Double Acting Operation Type--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith 2 Switches / A-C flow path detection / B-C Flow Path Detection

SGD 590.00

1 Piece(s) 16 Day(s) or more -2B2B-0~ 800~ 1.0Double-acting operation type (standard)Bronze (standard)Without switch (standard)--

-

1 Piece(s) 12 Day(s) or more Bronze2B2BT Port0~800~1.0Double Acting Operation Type---With no switch

-

1 Piece(s) 12 Day(s) or more Bronze2B2BT Port0~800~1.0Double Acting Operation Type---With 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 12 Day(s) or more Stainless Steel2B2BT Port0~800~1.0Double Acting Operation Type--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith no switch

-

1 Piece(s) 12 Day(s) or more Stainless Steel2B2BT Port0~800~1.0Double Acting Operation Type--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 11 Day(s) or more Bronze1/2B1/2BT Port0~800~1.0Single Action Type, Constant B-C Flow Path---With no switch

-

1 Piece(s) 11 Day(s) or more Bronze1/2B1/2BT Port0~800~1.0Single Action Type, Constant B-C Flow Path---With 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 11 Day(s) or more Stainless Steel1/2B1/2BT Port0~800~1.0Single Action Type, Constant B-C Flow Path--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith no switch

-

1 Piece(s) 11 Day(s) or more Stainless Steel1/2B1/2BT Port0~800~1.0Single Action Type, Constant B-C Flow Path--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 11 Day(s) or more Bronze3/4B3/4BT Port0~800~1.0Single Action Type, Constant B-C Flow Path---With no switch

-

1 Piece(s) 11 Day(s) or more Bronze3/4B3/4BT Port0~800~1.0Single Action Type, Constant B-C Flow Path---With 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 11 Day(s) or more Stainless Steel3/4B3/4BT Port0~800~1.0Single Action Type, Constant B-C Flow Path--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith no switch

-

1 Piece(s) 11 Day(s) or more Stainless Steel3/4B3/4BT Port0~800~1.0Single Action Type, Constant B-C Flow Path--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 11 Day(s) or more Bronze1B1BT Port0~800~1.0Single Action Type, Constant B-C Flow Path---With no switch

-

1 Piece(s) 11 Day(s) or more Bronze1B1BT Port0~800~1.0Single Action Type, Constant B-C Flow Path---With 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 11 Day(s) or more Stainless Steel1B1BT Port0~800~1.0Single Action Type, Constant B-C Flow Path--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith no switch

-

1 Piece(s) 11 Day(s) or more Stainless Steel1B1BT Port0~800~1.0Single Action Type, Constant B-C Flow Path--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 12 Day(s) or more Bronze1 1/4B1 1/4BT Port0~800~1.0Single Action Type, Constant B-C Flow Path---With no switch

-

1 Piece(s) 12 Day(s) or more Bronze1 1/4B1 1/4BT Port0~800~1.0Single Action Type, Constant B-C Flow Path---With 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 12 Day(s) or more Stainless Steel1 1/4B1 1/4BT Port0~800~1.0Single Action Type, Constant B-C Flow Path--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith no switch

-

1 Piece(s) 12 Day(s) or more Stainless Steel1 1/4B1 1/4BT Port0~800~1.0Single Action Type, Constant B-C Flow Path--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 12 Day(s) or more Bronze1 1/2B1 1/2BT Port0~800~1.0Single Action Type, Constant B-C Flow Path---With no switch

-

1 Piece(s) 12 Day(s) or more Stainless Steel1 1/2B1 1/2BT Port0~800~1.0Single Action Type, Constant B-C Flow Path--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith no switch

-

1 Piece(s) 12 Day(s) or more Bronze2B2BT Port0~800~1.0Single Action Type, Constant B-C Flow Path---With no switch

-

1 Piece(s) 12 Day(s) or more Stainless Steel2B2BT Port0~800~1.0Single Action Type, Constant B-C Flow Path--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith no switch

-

1 Piece(s) 12 Day(s) or more Bronze1/2B1/2BT Port0~800~1.0Single Action Type, Constant A-C Flow Path---With no switch

-

1 Piece(s) 12 Day(s) or more Bronze1/2B1/2BT Port0~800~1.0Single Action Type, Constant A-C Flow Path---With 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 12 Day(s) or more Stainless Steel1/2B1/2BT Port0~800~1.0Single Action Type, Constant A-C Flow Path--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith no switch

-

1 Piece(s) 12 Day(s) or more Stainless Steel1/2B1/2BT Port0~800~1.0Single Action Type, Constant A-C Flow Path--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 12 Day(s) or more Bronze3/4B3/4BT Port0~800~1.0Single Action Type, Constant A-C Flow Path---With no switch

-

1 Piece(s) 12 Day(s) or more Bronze3/4B3/4BT Port0~800~1.0Single Action Type, Constant A-C Flow Path---With 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 12 Day(s) or more Stainless Steel3/4B3/4BT Port0~800~1.0Single Action Type, Constant A-C Flow Path--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith no switch

-

1 Piece(s) 12 Day(s) or more Stainless Steel3/4B3/4BT Port0~800~1.0Single Action Type, Constant A-C Flow Path--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 12 Day(s) or more Bronze1B1BT Port0~800~1.0Single Action Type, Constant A-C Flow Path---With no switch

-

1 Piece(s) 12 Day(s) or more Bronze1B1BT Port0~800~1.0Single Action Type, Constant A-C Flow Path---With 2 Switches / A-C flow path detection / B-C Flow Path Detection

-

1 Piece(s) 12 Day(s) or more Stainless Steel1B1BT Port0~800~1.0Single Action Type, Constant A-C Flow Path--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith no switch

-

1 Piece(s) 12 Day(s) or more Stainless Steel1B1BT Port0~800~1.0Single Action Type, Constant A-C Flow Path--Stainless Steel (SCS13) / Stainless Steel (SCS13), Non-Oil SpecificationWith 2 Switches / A-C flow path detection / B-C Flow Path Detection

Loading...

Basic Information

Main Body Shape Upright 3-Way Applicable Fluid Water / Air / Oil Ball Valve Type Standard bore
Supply Side, Connection Type Rc Control Side, Connection Type Rc Operation Method Electric

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211