Male Elbow KPL Clean One-Touch Fitting (KPL06-01)

Male Elbow KPL Clean One-Touch Fitting KPL06-01
  • On Sale Till 31/03/2025
  • Volume Discount

A one-touch coupling from SMC Corporation.
[Features]
· A one-touch fitting; ideal for blowing type systems in clean rooms.
· Completely oil-free processing. (rubber parts are fluorine coated)
· Liquid-contact areas are non-metallic.
· Parts are cleaned, assembled and double packaged in a clean room.
· Can also be used in vacuums. (-100 kPa)
[Applications]
· Use to connect piping in a perpendicular orientation from female threads.

(i)Caution

  • *See the catalog for detailed specs and materials.
  • Product images may be representative images. Refer to the catalog for details.

PDF

Male Elbow KPL Outline Drawing And Dimensions

Male Elbow KPL outline drawing

Male Elbow KPL outline drawing

Applicable tube outer diameter
mm
Connection thread
R
ModelH
(width across flats)
Note 1:
øD1
øD2L1L2*AMEffective area
mm2
Weight
g
TPHTPS
41/8KPL04-011210.41019.723.224.5173.53.54
1/4KPL04-021427.226.55
61/8KPL06-011212.821.824.42718.5995
1/4KPL06-021428.4296
81/8KPL08-0115.21225.326.63020.522158
1/4KPL08-0229.431.59
101/4KPL10-021718.51728.432.135.523352513
3/8KPL10-0333.136.514
123/8KPL12-0320.930.434.338.524504015
1/2KPL12-04222238.341.518

*Reference dimensions after screwing in R thread
Note 1: øD1 indicates the maximum diameter.

Clean One-Touch Fitting For Blowing KP Series Common Specifications (Reference)

Applicable Tube

Tube materialsPFA, polyolefin
Soft polyolefin, polyurethane
Tube outer diameterø4, ø6, ø8, ø10, ø12

Note 1: FEP, nylon, soft nylon and other non-clean specification tubes can be used, but performance in terms of cleanliness will be reduced.
Note 2: Because polyurethane is a soft material, the tube may break when inserting. Hold the tube at its base and insert securely so that it reaches the back.

Specifications

Cleanliness class (ISO class)Class 3 Note 1:
Usable fluidsAir, nitrogen gas, water, deionized water (pure water) Note 2:
Maximum operating pressure (20°C)1 MPa Note 3:
Operating vacuum pressure-100 kPa {10 Torr}
Guaranteed proof pressure (20°C)3 MPa
Ambient temperature and working fluid temperature-20°C to 80°C
ThreadJIS B0203 (tapered thread for pipes/tubes)

Note 1: See the "Particle emissions grade classifications" below.
Note 2: Make sure the surge pressure stays below the maximum operating pressure.
Note 3: The maximum operating pressure is the value at 20°C. For other temperatures, see "Relationship between operating temperature and maximum operating pressure" below.
Note 4: It is not completely airtight, so please avoid use in leak testers, etc., where a vacuum is maintained.

Particle Emissions Grade Classifications

Particle emissions grade classifications graph

Particle emissions grade classifications graph

Relationship Between Operating Temperature And Maximum Operating Pressure

Operating temperature and maximum operating pressure graph

Operating temperature and maximum operating pressure graph

Model Indication Method

Clean One-Touch Fitting For Blowing KP Series model indication method

Clean One-Touch Fitting For Blowing KP Series model indication method

Structural Drawing And Components

Clean One-Touch Fitting For Blowing KP Series structural drawing

Clean One-Touch Fitting For Blowing KP Series structural drawing

NumberPart nameMaterials
1BodyPP
2StudPP
3ChuckSUS304
4GuideSUS304
5Release buttonPP (Color: light green)
6ColletPP
7StopperSUS304
8SealEPDM (fluorine coating)
9BumperEPDM (fluorine coating)
10O-ringEPDM (fluorine coating)
11Drive bushingSUS304

Usage Precautions

  • The KP Series is composed of dedicated one-touch fittings for clean blow and cleaning lines.
  • Seal material used: Since the durability of EPDM degrades when exposed to mineral oils, it is not suitable for general pneumatic equipment piping.
Part Number
KPL06-01
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipApplicable Tube O.D.1
(φ)
Connection screw

SGD 9.22

1 Piece(s)Available 32 Day(s) 61/8

Loading...

  1. 1

Basic Information

Types Single-Action / Screw Fitting Type Screw Mount Direction Applicable Fluid Water / Air / Nitrogen Gas
Body Material PP-SUS304 Application Clean circumstance Thread Material SUS304
Packing, Material of O-Ring EPDM (Fluorine Coating) Screw Mounting, Direction Elbow Elbows Elbow Union
Operating Temperature(°C) -20::80 Types of connection R Tube Material PFA, Polyolefin, Soft Polyolefin, Polyurethane
Release button color Light Green Custom-made specifications N/A

Please check the type/dimensions/specifications of the part KPL06-01 in the Male Elbow KPL Clean One-Touch Fitting series.

Similar Part Numbers

Part Number
KPL04-01
KPL04-02
KPL06-02
KPL08-01
KPL08-02
KPL10-02
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipApplicable Tube O.D.1
(φ)
Connection screw

SGD 9.22

1 Piece(s)Available Same day 41/8

SGD 9.22

1 Piece(s)Available 31 Day(s) 41/4

SGD 9.22

1 Piece(s)Available 32 Day(s) 61/4

SGD 9.57

1 Piece(s)Available 32 Day(s) 81/8

SGD 9.57

1 Piece(s)Available 32 Day(s) 81/4

SGD 10.73

1 Piece(s)Available 32 Day(s) 101/4

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)