Smart Fiber Amplifier E3NX-MA (Part Numbers)

Part Number

Configured Part Number is shown.

Drawing

Pre-Wired Type

Smart fiber amplifier E3NX-MA, pre-wired type, drawing

Wire saving connector type

Smart fiber amplifier E3NX-MA, wire saving connector type, drawing

Connector type for sensor communication unit

Smart fiber amplifier E3NX-MA, connector type for sensor communication unit, drawing

Product Specifications

Rating/Performance

ItemNPN outputModel E3NX-MA11Model E3NX-MA6Model E3NX-MA0
PNP outputModel E3NX-MA41Model E3NX-MA8
Connection methodPre-wiredWire saving connectorConnector for sensor communication unit
TypeStandard typeFor sensor communication unit
Input/outputOutput2 Output-*1
External input
Light source (emission wavelength)Red 4-element light emitting diode (625 nm)
Power supply voltage10 to 30 V DC, ripple (p-p) 10% includedSupplied from the connector
through the sensor communication unit
Power consumption*2At 24 V power supply voltage
Normal mode: 960 mW or less (current consumption: 40 mA or less)
Eco function ON: 770 mW or less (current consumption: 32 mA or less)
Eco function LO: 870 mW or less (current consumption: 36 mA or less)
Control outputLoad power supply voltage: 30 V DC or less, open collector output type
(Depends on NPN/PNP output format)
Load current: 100 mA or less when connecting 1 to 3 units, 20 mA or less when connecting 4 or more units
(residual voltage, less than 10 mA load current: 1 V or less, 10 to 100 mA load current: 2 V or less)
Off-state current: 0.1 mA or less
Indicator light7-segment display (sub-digital display: green, main digital display: white)
Display direction: Normal / reverse display switchable
OUT indicator light (orange), L/D indicator light (orange), ST indicator light (blue), DPC indicator light (green), OUT selection indicator light (orange)
Protection circuitPower supply reverse connection protection, output short circuit protection, output reverse connection protectionPower supply reverse connection protection,
Output short circuit protection
Response timeFastest mode (SHS)Operation and recovery: 100 µs each
high-speed mode (HS)Operation and recovery: 450 µs each
Standard mode (Stnd)Operation and recovery: 1 ms each
Giga power mode
(GIGA)
Operation and recovery: 16 ms each
Sensitivity AdjustmentSmart tuning (2-point tuning, full auto tuning, positioning tuning, maximum sensitivity tuning,
power tuning, percent tuning (-99% to +99%)) or manual adjustment
Maximum number of connected units30 units30 units*3 when using model E3NW-ECT
16 units when using model E3NW-CCL
Mutual interference prevention units*49 units. Note: When the detection function is set to the fastest mode (SHS), the mutual interference prevention function is disabled.

* 1. 2 sensor outputs are assigned to the PLC through the network.
    Various settings can be changed and detected values can be read by operating the PLC via the network.
* 2. Power consumption
    When the power supply voltage is 10 V to 30 V
    Normal mode: 1,080 mW or less (36 mA or less current consumption at 30 V power supply voltage / 75 mA or less current consumption at 10 V power supply voltage)
    Eco function ON: 840 mW or less (28 mA or less current consumption at 30 V power supply voltage / 55 mA or less current consumption at 10 V power supply voltage)
    Eco function LO: 960 mW or less (32 mA or less current consumption at 30 V power supply voltage / 65 mA or less current consumption at 10 V power supply voltage)
* 3. When connected to the Omron NJ series.
* 4. Tuning does not change the number of units.
    This is the smallest number of mutual interference prevention units for the models E3NX and E3NC. Check the number of mutual interference prevention units and response speed for each model.

 
ItemNPN outputModel E3NX-MA11Model E3NX-MA6Model E3NX-MAO
PNP outputModel E3NX-MA41Model E3NX-MA8
Connection methodPre-wiredWire saving connectorConnector for sensor communication unit
TypeStandard typeFor sensor communication unit
FunctionAuto power
control (APC)
Available (always enabled)
Dynamic
power control
(DPC)
Available
TimerSelectable from timer function disabled, off-delay, on-delay, one-shot, and on/off-delay. 1 ms to 9,999 ms
Zero resetNegative display possible (The threshold also shifts)
Reset settings*5Selectable from initial reset (factory default) / user reset (saved)
Eco-modeSelectable from OFF (digital display on) / ECO ON (digital display off) / ECO LO (digital display dark on)
Bank switching settingSelectable from bank 1 to 4
Power tuning
at the time of shipment
Selectable from ON/OFF
Output 1 settingSelectable from normal detection mode and area detection mode
Output 2 settingSelectable from normal detection mode, AND output mode, OR output mode, XOR output mode, GAP output mode,
rising edge synchronous mode, falling edge synchronous mode, and area detection mode
Hysteresis width settingSelectable from standard settings or user settings. In case of user settings, hysteresis width can be set from 0 to 9,999
Ambient illuminance usedLight receiving surface illuminance, Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less
Ambient temperature range*6During operation:
When connecting 1 to 2 units: -25°C to +55°C,
When connecting 3 to 10 units: -25°C to +50°C,
When connecting 11 to 16 units: -25°C to +45°C,
When connecting 17 to 30 units: -25°C to +40°C
When storing: -30 to +70°C
(no freezing or condensation)
During operation:
When connecting 1 to 2 units: 0 to +55°C,
When connecting 3 to 10 units: 0°C to +50°C,
When connecting 11 to 16 units: 0°C to +45°C,
When connecting 17 to 30 units: 0°C to +40°C
When storing: -30°C to +70°C
(no freezing or condensation)
Ambient humidity rangeWhen operating/storing: 35 to 85% RH each in the above ambient temperature range (no condensation)
Altitude2,000 m or less
Installation environmentPollution degree 3
Insulation resistance20 MΩ or more (by 500 V DC insulation resistance tester)
Withstand voltage1,000 V AC 50/60 Hz for 1 min
Vibration (Resistance)10 to 55 Hz, double amplitude 1.5 mm for 2 hours in each direction of X, Y, Z
Impact (Resistance)500 m/s^2, 3 times in each direction of X, Y, Z150 m/s^2, 3 times in each direction of X, Y, Z
Protective structureIEC standard IP50
Weight (Packaging state / main unit only)Approx. 115 g / approx. 75 gApprox. 60 g / approx. 20 gApprox. 65 g / approx. 25 g
MaterialsCasePolycarbonate (PC)
CoverPolycarbonate (PC)
CordPVC (PVC)
AccessoriesInstruction manual

* 5. BANK is not reset by user reset and is not saved by user save.
* 6. If the number of connected units is 11 or more, the ambient temperature range will be less than 50°C.

Part Number
E3NX-MA0
E3NX-MA6
E3NX-MA8
E3NX-MA11 2M
E3NX-MA41 2M
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipProduct Type Output Format Connection Method Cord Length
(m)
Input/Output (Amplifier)

SGD 294.90

1 Piece(s) 14 Day(s) or more Sensor communication unit type-Connector for sensor communication unit--

SGD 291.32

1 Piece(s) 9 Day(s) or more Standard typeNPNWire saving connector type-2 Output

SGD 291.32

1 Piece(s) 14 Day(s) or more Standard typePNPWire saving connector type-2 Output

SGD 295.22

1 Piece(s) 7 Day(s) or more Standard typeNPNPre-wired type22 Output

SGD 295.22

1 Piece(s) 14 Day(s) or more Standard typePNPPre-wired type22 Output

Loading...

  1. 1
 

Basic Information

Response Time(ms) 1 (standard mode)

Tech Support