(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Pressure sensor, SPAU Series (SPAU-P10R-T-R18M-L-PNLK-PNVBA-M8D)

Part Number

Configured Part Number is shown.

SPAU-P10R-T-R18M-L-PNLK-PNVBA-M8D

Pressure sensor, SPAU Series

Features

 Pressure sensor, SPAU Series

The pressure sensor SPAU is suitable for monitoring compressed air and noncorrosive gases. The variant with display offers the option of reading the pressure and set values on-site. The pressure value is transmitted to the connected control system as a switching signal, as an analogue signal or via IO-Link.
 Pressure sensor, SPAU Series

The pressure sensor without display transmits the pressure value to the connected control system as an analogue signal. Display of the pressure and parameterisation of the sensor are provided centrally, e.g. via a display that is part of a machine control system. The pressure sensor can be parameterised using IO-Link as a tamper-proof pressure switch without display with up to two switching outputs.

Areas of application

• Network monitoring (pressure present)
• Regulator monitoring (pressure in the setpoint range)
• Vacuum (part picked up)
• Leak test (pressure drop over time)
• Object detection (back pressure present)

Product benefits

A mounting concept that is quick to mount and that is easy to implement in all installation situations. Female/male thread or push-in fitting QS – the perfect pneumatic adapter for every application.

Mounting:
• Threaded mounting
• H-rail mounting
• Front panel mounting
• Mounting bracket
• Wall mounting
• Adapter to MS4, MS6

Electronics:
• Maximum versatility and reduced warehousing thanks to switchable electrical outputs (PNP/NPN/N/C contact/N/O contact and current/ voltage output)

Part Number
SPAU-P10R-T-R18M-L-PNLK-PNVBA-M8D
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOperating Temperature Range
(°C)
IP Pneumatic connection Display type Switching output Switching element function Min. Temperature of medium
(°C)
IP rating DC operating voltage range
(V)
Pressure measuring range initial value
(bar)
Pressure measuring range end value
(bar)
Max. overload pressure
(bar)
Operating medium Accuracy in ± % FS ADC resolution Ambient temperature Analog output
(V)
Certification Displayable unit(s) Electrical connection 1, connection technology Electrical connection 1, connection type Electrical connection 1, number of pins/wires Electrical connection for input 1, connection pattern Information on operating and pilot media IO-Link®, communication mode IO-Link®, data memory required
(byte)
IO-Link®, function classes IO-Link®, minimum cycle time
(ms)
IO-Link®, port class IO-Link®, process data content IN IO-Link®, process data width IN
(Byte)
IO-Link®, process data width OUT
(Byte)
IO-Link®, profile IO-Link®, protocol version IO-Link®, SIO mode support KC characters LABS (PWIS) conformity Max. load resistance of current output
(Ohm)
Measured variable Method of measurement Min. load resistance of voltage output
(kOhm)
Mounting position Note on materials Protection against tampering Protocol Reverse polarity protection Rise time
(ms)
Setting options Setting range hysteresis
(%)
Setting range threshold value
(%)
Short-circuit protection Switching function Temperature co-efficient in ± %FS/K Type of mounting UKCA marking (see declaration of conformity) Manufacturer part # Weight
(g)

SGD 249.50

1 Piece(s) Quote 0~50IP67R1/8Illuminated LCD2 x PNP or 2 x NPN switchableN/C contact/N/O contact switchable0IP65, IP6720-3001015Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas------------------------------------------800120380

Loading...

  1. 1
 

Basic Information

Max. output current(mA) 100 Max. Temperature of medium(°C) 50 Repetition accuracy in ± %FS 0.3 %FS
Corrosion resistance class (CRC) 2 - Moderate corrosion stress

Please check the type/dimensions/specifications of the part SPAU-P10R-T-R18M-L-PNLK-PNVBA-M8D in the Pressure sensor, SPAU Series series.

Similar Part Numbers

Part Number
SPAU-P10R-F-Q6-L-PNLK-PNVBA-M12
SPAU-P10R-H-G18FD-L-PNLK-PNVBA-M12U
SPAU-P10R-H-G18FD-L-PNLK-PNVBA-M8U
SPAU-P10R-W-G18FD-L-PNLK-PNVBA-M12U
SPAU-P10R-W-G18FD-L-PNLK-PNVBA-M8U
SPAU-P10R-W-Q4D-L-PNLK-PNVBA-M12D
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOperating Temperature Range
(°C)
IP Pneumatic connection Display type Switching output Switching element function Min. Temperature of medium
(°C)
IP rating DC operating voltage range
(V)
Pressure measuring range initial value
(bar)
Pressure measuring range end value
(bar)
Max. overload pressure
(bar)
Operating medium Accuracy in ± % FS ADC resolution Ambient temperature Analog output
(V)
Certification Displayable unit(s) Electrical connection 1, connection technology Electrical connection 1, connection type Electrical connection 1, number of pins/wires Electrical connection for input 1, connection pattern Information on operating and pilot media IO-Link®, communication mode IO-Link®, data memory required
(byte)
IO-Link®, function classes IO-Link®, minimum cycle time
(ms)
IO-Link®, port class IO-Link®, process data content IN IO-Link®, process data width IN
(Byte)
IO-Link®, process data width OUT
(Byte)
IO-Link®, profile IO-Link®, protocol version IO-Link®, SIO mode support KC characters LABS (PWIS) conformity Max. load resistance of current output
(Ohm)
Measured variable Method of measurement Min. load resistance of voltage output
(kOhm)
Mounting position Note on materials Protection against tampering Protocol Reverse polarity protection Rise time
(ms)
Setting options Setting range hysteresis
(%)
Setting range threshold value
(%)
Short-circuit protection Switching function Temperature co-efficient in ± %FS/K Type of mounting UKCA marking (see declaration of conformity) Manufacturer part # Weight
(g)

SGD 266.15

1 Piece(s) Quote 0~50IP67QS-6Illuminated LCD2 x PNP or 2 x NPN switchableN/C contact/N/O contact switchable0IP65, IP6720-3001015Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas------------------------------------------800122570

SGD 250.80

1 Piece(s) Quote --G1/8Illuminated LCD2 x PNP or 2 x NPN switchableN/C contact/N/O contact switchable0IP65, IP6720-3001015Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas1.5 %FS12 bit0 °C ... 50 °C0 - 10 V, 4 - 20 mA, 1 - 5 VRCM compliance mark, c UL us - Listed (OL)Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psiM12x1 A-coded as per EN 61076-2-101Plug4995386Operation with oil lubrication possibleCOM2 (38,4 kBd)500Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel3A14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring)20Smart sensor profileDevice V 1.1YesKC EMCVDMA24364-B1/B2-L500Relative pressurePiezoresistive pressure sensor10AnyRoHS-compliantIO-Link®, PIN codeIO-Link®for all electrical connections3IO-Link®, Teach-in, Via display and pushbuttons0-900-100yesFreely programmable0.05 %FS/KWith H-railTo UK instructions for EMC, To UK RoHS instructions800122070

SGD 244.40

1 Piece(s) Quote 0~50IP67G1/8Illuminated LCD2xPNP or 2xNPN switchableN/C contact, N/O contact, Switchable0IP65, IP6720-3001015Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas------------------------------------------800122170

SGD 263.35

1 Piece(s) Quote --G1/8Illuminated LCD2 x PNP or 2 x NPN switchableN/C contact/N/O contact switchable0IP65, IP6720-3001015Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas1.5 %FS12 bit0 °C ... 50 °C0 - 10 V, 4 - 20 mA, 1 - 5 VRCM compliance mark, c UL us - Listed (OL)Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psiM12x1 A-coded as per EN 61076-2-101Plug4995386Operation with oil lubrication possibleCOM2 (38,4 kBd)500Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel3A14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring)20Smart sensor profileDevice V 1.1YesKC EMCVDMA24364-B1/B2-L500Relative pressurePiezoresistive pressure sensor10AnyRoHS-compliantIO-Link®, PIN codeIO-Link®for all electrical connections3IO-Link®, Teach-in, Via display and pushbuttons0-900-100yesFreely programmable0.05 %FS/KWith wall/surface bracketTo UK instructions for EMC, To UK RoHS instructions800123070

SGD 256.95

1 Piece(s) Quote 0~50IP67G1/8Illuminated LCD2 x PNP or 2 x NPN switchableN/C contact/N/O contact switchable0IP65, IP6720-3001015Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas------------------------------------------800123170

SGD 253.10

1 Piece(s) Quote 0~50IP67QS-4Illuminated LCD2 x PNP or 2 x NPN switchableN/C contact/N/O contact switchable0IP65, IP6720-3001015Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas------------------------------------------800123665

Tech Support