(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 23/2 to 7:00 (SGT) 24/2/2025. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Rotary actuator, DFPD Series (Part Numbers)

Part Number

Configured Part Number is shown.

Rotary actuator, DFPD Series

Rotary actuator, DFPD Series
Rotary actuator, DFPD Series

Features

Rotary actuator, DFPD Series

Specifications

Size10204080120160
Mode of operationDouble-acting
DesignGear rack/pinion
CushioningNo cushioning
Mounting positionAny
Pneumatic connectionG1/8G1/4
1/8 NPT1/4 NPT
Process valve connection to standardISO 5211
Valve connection conforms to standardVDI/VDE 3845 (NAMUR)
Connection for positioner and 
position sensor conforms to standard
VDI/VDE 3845 (NAMUR)
Safety Integrity Level (SIL)Up to SIL 2 high demand mode
SizeAA 1
Flange hole pattern 1F03F04F03F04F05F04F05F05F05F07
Flange hole pattern 2-----F07F07F07F07F10
Swivel angle [°]90
-120-120-
-135-135-
-180-180-
End-position adjusting range [°] at 0°-5 to +5
End-position adjusting range [°] at 90°-5 to +5
End-position adjusting range at 180°--5 to +5--5 to +5-
Position sensingOptical
Closing directionCloses to the right
Part Number
DFPD-2300-RP-90-RD-F1216
DFPD-2300-RP-90-RD-F1216-R3-EP
DFPD-2300-RP-90-RS35-F16-R3-C
DFPD-2300-RP-90-RS35-F16-R3-C-VDE2
DFPD-2300-RP-90-RS35-F16-X-R3-C
DFPD-2300-RP-90-RS35-F16-X-R3-C-VDE2
DFPD-2300-RP-90-RS45-F16-R3-C
DFPD-2300-RP-90-RS45-F16-R3-C-VDE2
DFPD-2300-RP-90-RS45-F16-X-R3-C
DFPD-2300-RP-90-RS45-F16-X-R3-C-VDE2
DFPD-2300-RP-90-RS60-F16-R3-C
DFPD-2300-RP-90-RS60-F16-R3-C-VDE2
DFPD-2300-RP-90-RS60-F16-X-R3-C
DFPD-2300-RP-90-RS60-F16-X-R3-C-VDE2
DFPD-2300-RP-90-RS60-F1216
DFPD-2300-RP-90-RS60-F1216-R3-EP
DFPD-240-RP-90-RD-F0710
DFPD-240-RP-90-RD-F0710-R3-EP
DFPD-240-RP-90-RS30-F0710
DFPD-240-RP-90-RS30-F0710-R3-EP
DFPD-240-RP-90-RS35-F10-R3-C
DFPD-240-RP-90-RS35-F10-R3-C-VDE2
DFPD-240-RP-90-RS45-F10-R3-C
DFPD-240-RP-90-RS45-F10-R3-C-VDE2
DFPD-240-RP-90-RS60-F0710
DFPD-240-RP-90-RS60-F0710-R3-EP
DFPD-240-RP-90-RS60-F10-R3-C
DFPD-240-RP-90-RS60-F10-R3-C-VDE2
DFPD-240-RP-180-RD-F0710
DFPD-300-RP-90-RD-F0710
DFPD-300-RP-90-RD-F0710-R3-EP
DFPD-300-RP-90-RS30-F0710
DFPD-300-RP-90-RS30-F0710-R3-EP
DFPD-300-RP-90-RS35-F10-R3-C
DFPD-300-RP-90-RS35-F10-R3-C-VDE2
DFPD-300-RP-90-RS45-F10-R3-C
DFPD-300-RP-90-RS45-F10-R3-C-VDE2
DFPD-300-RP-90-RS60-F0710
DFPD-300-RP-90-RS60-F0710-R3-EP
DFPD-300-RP-90-RS60-F10-R3-C
DFPD-300-RP-90-RS60-F10-R3-C-VDE2
DFPD-480-RP-90-RD-F1012
DFPD-480-RP-90-RD-F1012-R3-EP
DFPD-480-RP-90-RS30-F1012
DFPD-480-RP-90-RS30-F1012-R3-EP
DFPD-480-RP-90-RS35-F12-R3-C
DFPD-480-RP-90-RS35-F12-R3-C-VDE2
DFPD-480-RP-90-RS45-F12-R3-C
DFPD-480-RP-90-RS45-F12-R3-C-VDE2
DFPD-480-RP-90-RS60-F12-R3-C
DFPD-480-RP-90-RS60-F12-R3-C-VDE2
DFPD-480-RP-90-RS60-F1012
DFPD-480-RP-90-RS60-F1012-R3-EP
DFPD-480-RP-120-RD-F1012
DFPD-480-RP-180-RD-F1012
DFPD-700-RP-90-RD-F1012-R3-EP
DFPD-700-RP-90-RS35-F12-R3-C
DFPD-700-RP-90-RS35-F12-R3-C-VDE2
DFPD-700-RP-90-RS45-F12-R3-C
DFPD-700-RP-90-RS45-F12-R3-C-VDE2
DFPD-700-RP-90-RS60-F12-R3-C
DFPD-700-RP-90-RS60-F12-R3-C-VDE2
DFPD-700-RP-90-RS60-F1012
DFPD-700-RP-90-RS60-F1012-R3-EP
DFPD-900-RP-90-RD-F14
DFPD-900-RP-90-RD-F14-R3-EP
DFPD-900-RP-90-RS35-F14-R3-C
DFPD-900-RP-90-RS35-F14-R3-C-VDE2
DFPD-900-RP-90-RS45-F14-R3-C
DFPD-900-RP-90-RS45-F14-R3-C-VDE2
DFPD-900-RP-90-RS60-F14
DFPD-900-RP-90-RS60-F14-R3-C
DFPD-900-RP-90-RS60-F14-R3-C-VDE2
DFPD-900-RP-90-RS60-F14-R3-EP
DFPD-900-RP-90-RS60-F1012
DFPD-900-RP-90-RS60-F1012-R3-EP
DFPD-N-160-RP-90-RS35-F07-17-R3-C
DFPD-N-160-RP-90-RS45-F07-17-R3-C
DFPD-N-160-RP-90-RS60-F07-17-R3-C
DFPD-N-2300-RP-90-RS35-F16-X-R3-C
DFPD-N-2300-RP-90-RS45-F16-X-R3-C
DFPD-N-2300-RP-90-RS60-F16-X-R3-C
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOperating Pressure Range
(MPa)
Housing material Cover material Material of screws Shaft material Swivel angle
(deg)
Nominal operating pressure
(bar)
Min. Ambient temperature
(°C)
Max. Ambient temperature
(°C)
Min. Storage temperature
(°C)
Max. Storage temperature
(°C)
Pneumatic connection Size of valve actuator Depth shaft connection
(mm)
Torque at nominal operating pressure and 0° swivel angle
(Nm)
Torque at nominal operating pressure and 90° swivel angle
(Nm)
Operating medium Corrosion resistance class (CRC) Flange hole pattern End-position adjusting range at 0°
(deg)
End-position adjusting range at nominal swivel angle
(deg)
Standard connection for valve Mounting position Mode of operation Structural design Closing direction Valve connection conforms to standard Connection point for positioner and position sensor conforms to standard Devices type according to VDMA 66413 Safety function Safety integrity level (SIL) Certified for safety function to ISO 13849 and IEC 61508 (SIL) Maritime classification CE marking (see declaration of conformity) UKCA marking (see declaration of conformity) Explosion protection certification outside the EU Explosion prevention and protection Certificate issuing authority ATEX category gas ATEX category for dust Type of ignition protection for gas Type of (ignition) protection for dust Explosive ambient temperature
(°C)
Information on operating and pilot media LABS (PWIS) conformity MTTFd
(years)
PFH PFD Air consumption at 6 bar per cycle 0°-nominal swivel angle-0°
(l)
Shaft connection Note on materials Material of sub-base Material of piston Material of bearing Cam material Spring return torque at 0° swivel angle
(Nm)
Spring return torque with 90° swivel angle
(Nm)
Material of spring Manufacturer part # Weight
(g)

SGD 3,423.15

SGD 2,396.21

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelSteel, nickel-plated905.5-2080-2060G1/42300482233.32233.3Compressed air as per ISO 8573-1:2010 [7:4:4]2 - Moderate corrosion stress-----------------------------------------64900

SGD 4,552.80

SGD 3,186.96

1 Piece(s) Quote -Die-cast aluminum, coated---90-----G1/4------F1216------------------------------T46--Die-cast aluminum--2233.3 (at 0° swivel angle)2233.3 (with 90° swivel angle)---

SGD 5,485.60

SGD 3,839.92

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F16------------------------------T46--Die-cast aluminum--504.7 (at 0° swivel angle)857.2 (with 90° swivel angle)---

SGD 5,592.10

SGD 3,914.47

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F16------------------------------T46--Die-cast aluminum--504.7 (at 0° swivel angle)857.2 (with 90° swivel angle)---

-

1 Piece(s) 91 Day(s) 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel903.5-2080-2060G1/2230048916.5564-1 - Low corrosion stressF16-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 3Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007884.4T46RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel504.7857.2Spring steel72562

-

1 Piece(s) 61 Day(s) 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel903.5-2080-2060G1/2230048916.5564-1 - Low corrosion stressF16-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 3Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007884.4T46RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel504.7857.2Spring steel72531

SGD 5,673.90

SGD 3,971.73

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F16------------------------------T46--Die-cast aluminum--663.3 (at 0° swivel angle)1127 (with 90° swivel angle)---

SGD 5,780.40

SGD 4,046.28

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F16------------------------------T46--Die-cast aluminum--663.3 (at 0° swivel angle)1127 (with 90° swivel angle)---

-

1 Piece(s) 91 Day(s) 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel904.5-2080-2060G1/22300481163700.6-1 - Low corrosion stressF16-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 3Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007884.4T46RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel663.31127Spring steel74726

-

1 Piece(s) 61 Day(s) 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel904.5-2080-2060G1/22300481163700.6-1 - Low corrosion stressF16-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 3Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007884.4T46RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel663.31127Spring steel74695

SGD 5,956.25

SGD 4,169.38

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F16------------------------------T46--Die-cast aluminum--913.2 (at 0° swivel angle)1551 (with 90° swivel angle)---

SGD 6,062.80

SGD 4,243.96

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F16------------------------------T46--Die-cast aluminum--913.2 (at 0° swivel angle)1551 (with 90° swivel angle)---

-

1 Piece(s) 61 Day(s) 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel906-2080-2060G1/22300481523885.2-1 - Low corrosion stressF16-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 3Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007884.4T46RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel913.21551Spring steel77972

-

1 Piece(s) 31 Day(s) 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel906-2080-2060G1/22300481523885.2-1 - Low corrosion stressF16-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 3Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007884.4T46RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel913.21551Spring steel77941

SGD 4,450.10

SGD 3,115.07

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F1216------------------------------T46--Die-cast aluminum--913.2 (at 0° swivel angle)1551 (with 90° swivel angle)---

SGD 5,579.75

SGD 3,905.83

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel906-2080-2060G1/42300481523885.2-1 - Low corrosion stressF1216-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 3Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007884.4T46RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel913.21551Spring steel77884

SGD 601.10

SGD 420.77

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelSteel, nickel-plated905.5-2080-2060G1/424024234.3234.3Compressed air as per ISO 8573-1:2010 [7:4:4]2 - Moderate corrosion stress-----------------------------------------8594

SGD 775.70

SGD 542.99

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel905.5-2080-2060G1/424024234.3234.3-1 - Low corrosion stressF0710-5 ... 5-5 ... 5ISO 5211AnyDouble-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety devicenanUp to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0014220.3T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel---8594

SGD 630.95

SGD 441.67

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelSteel, nickel-plated903-2080-2060G1/42402485.844.8-1 - Low corrosion stressF0710-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.000788.6T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel4283Spring steel9442

SGD 805.50

SGD 563.85

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel903-2080-2060G1/42402485.844.8-1 - Low corrosion stressF0710-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.000788.6T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel4283Spring steel9442

SGD 970.55

SGD 679.39

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel903.5-2080-2060G1/424024100.152.2-1 - Low corrosion stressF10-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.000788.6T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel4996.9Spring steel9558

SGD 1,001.45

SGD 701.02

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel903.5-2080-2060G1/424024100.152.2-1 - Low corrosion stressF10-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.000788.6T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel4996.9Spring steel9539

SGD 979.95

SGD 685.97

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel904.5-2080-2060G1/424024128.767.1-1 - Low corrosion stressF10-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.000788.6T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel63124.6Spring steel9756

SGD 1,010.85

SGD 707.60

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel904.5-2080-2060G1/424024128.767.1-1 - Low corrosion stressF10-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.000788.6T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel63124.6Spring steel9737

SGD 656.60

SGD 459.62

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelSteel, nickel-plated906-2080-2060G1/424024171.689.5Compressed air as per ISO 8573-1:2010 [7:4:4]2 - Moderate corrosion stress-----------------------------------------10036

SGD 831.15

SGD 581.81

1 Piece(s) Quote -Die-cast aluminum, coated---90-----G1/4------F0710------------------------------T22--Die-cast aluminum--84 (at 0° swivel angle)166.1 (with 90° swivel angle)---

SGD 994.05

SGD 695.84

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel906-2080-2060G1/424024171.689.5-1 - Low corrosion stressF10-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.000788.6T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel84166.1Spring steel10053

SGD 1,024.95

SGD 717.47

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F10------------------------------T22--Die-cast aluminum--84 (at 0° swivel angle)166.1 (with 90° swivel angle)---

SGD 1,236.75

SGD 865.73

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelSteel, nickel-plated1805.5-2080-2060G1/424024234.3234.3-1 - Low corrosion stressF0710-5 ... 5-5 ... 5ISO 5211AnyDouble-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety devicenanUp to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0014225.7T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel---12549

SGD 695.45

SGD 486.82

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelSteel, nickel-plated905.5-2080-2060G1/430024301.9301.9Compressed air as per ISO 8573-1:2010 [7:4:4]2 - Moderate corrosion stress-----------------------------------------11224

SGD 928.20

SGD 649.74

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel905.5-2080-2060G1/430024301.9301.9-1 - Low corrosion stressF0710-5 ... 5-5 ... 5ISO 5211AnyDouble-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety devicenanUp to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0014226.4T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel---11224

SGD 721.00

SGD 504.70

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelSteel, nickel-plated903-2080-2060G1/430024110.557.6-1 - Low corrosion stressF0710-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007811T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel54.2107Spring steel12052

SGD 953.70

SGD 667.59

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel903-2080-2060G1/430024110.557.6-1 - Low corrosion stressF0710-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007811T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel54.2107Spring steel12052

SGD 1,114.50

SGD 780.15

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel903.5-2080-2060G1/430024128.967.2-1 - Low corrosion stressF10-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007811T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel63.2124.9Spring steel12209

SGD 1,145.45

SGD 801.82

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel903.5-2080-2060G1/430024128.967.2-1 - Low corrosion stressF10-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007811T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel63.2124.9Spring steel12187

SGD 1,127.00

SGD 788.90

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F10------------------------------T22--Die-cast aluminum--81.3 (at 0° swivel angle)160.6 (with 90° swivel angle)---

SGD 1,157.90

SGD 810.53

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel904.5-2080-2060G1/430024165.786.4-1 - Low corrosion stressF10-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007811T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel81.3160.6Spring steel12463

SGD 746.50

SGD 522.55

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelSteel, nickel-plated906-2080-2060G1/430024221115.3Compressed air as per ISO 8573-1:2010 [7:4:4]2 - Moderate corrosion stress-----------------------------------------12880

SGD 979.20

SGD 685.44

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel906-2080-2060G1/430024221115.3-1 - Low corrosion stressF0710-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007811T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel108.4214.1Spring steel12880

SGD 1,145.70

SGD 801.99

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel906-2080-2060G1/430024221115.3-1 - Low corrosion stressF10-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007811T22RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel108.4214.1Spring steel12899

SGD 1,176.65

SGD 823.66

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F10------------------------------T22--Die-cast aluminum--108.4 (at 0° swivel angle)214.1 (with 90° swivel angle)---

SGD 1,053.30

SGD 737.31

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelSteel, nickel-plated905.5-2080-2060G1/448029474474Compressed air as per ISO 8573-1:2010 [7:4:4]2 - Moderate corrosion stress-----------------------------------------16025

SGD 1,399.25

SGD 979.48

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel905.5-2080-2060G1/448029474474-1 - Low corrosion stressF1012-5 ... 5-5 ... 5ISO 5211AnyDouble-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety devicenanUp to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0014240.5T27RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel---16025

SGD 1,145.35

SGD 801.75

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelSteel, nickel-plated903-2080-2060G1/448029173.590.5-1 - Low corrosion stressF1012-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007817.2T27RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel85168.1Spring steel17261

SGD 1,491.30

SGD 1,043.91

1 Piece(s) Quote -Die-cast aluminum, coated---90-----G1/4------F1012------------------------------T27--Die-cast aluminum--85 (at 0° swivel angle)168.1 (with 90° swivel angle)---

SGD 1,595.90

SGD 1,117.13

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F12------------------------------T27--Die-cast aluminum--99.2 (at 0° swivel angle)196.1 (with 90° swivel angle)---

SGD 1,628.05

SGD 1,139.64

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel903.5-2080-2060G1/448029202.4105.6-1 - Low corrosion stressF12-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007817.2T27RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel99.2196.1Spring steel17848

SGD 1,629.65

SGD 1,140.76

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F12------------------------------T27--Die-cast aluminum--127.5 (at 0° swivel angle)252.1 (with 90° swivel angle)---

SGD 1,661.80

SGD 1,163.26

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F12------------------------------T27--Die-cast aluminum--127.5 (at 0° swivel angle)252.1 (with 90° swivel angle)---

SGD 1,680.30

SGD 1,176.21

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel906-2080-2060G1/448029347.1181-1 - Low corrosion stressF12-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007817.2T27RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel170336.1Spring steel18518

SGD 1,712.45

SGD 1,198.72

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel906-2080-2060G1/448029347.1181-1 - Low corrosion stressF12-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007817.2T27RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel170336.1Spring steel18504

SGD 1,237.50

SGD 866.25

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelSteel, nickel-plated906-2080-2060G1/448029347.1181Compressed air as per ISO 8573-1:2010 [7:4:4]2 - Moderate corrosion stress-----------------------------------------18485

SGD 1,583.45

SGD 1,108.42

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel906-2080-2060G1/448029347.1181-1 - Low corrosion stressF1012-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007817.2T27RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel170336.1Spring steel18485

SGD 2,058.50

SGD 1,440.95

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelSteel, nickel-plated1205.5-2080-2060G1/448029474474-1 - Low corrosion stressF1012-5 ... 5-5 ... 5ISO 5211AnyDouble-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety devicenanUp to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0014248.3T27RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel---20653

SGD 2,145.80

SGD 1,502.06

1 Piece(s) Quote -Anodised wrought aluminium alloy---180-----G1/4------F1012------------------------------T27--Die-cast aluminum-------

SGD 1,698.55

SGD 1,188.99

1 Piece(s) Quote -Die-cast aluminum, coated---90-----G1/4------F1012------------------------------T27--Die-cast aluminum-------

SGD 2,033.90

SGD 1,423.73

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F12------------------------------T27--Die-cast aluminum--142.6 (at 0° swivel angle)260.1 (with 90° swivel angle)---

SGD 2,073.60

SGD 1,451.52

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F12------------------------------T27--Die-cast aluminum--142.6 (at 0° swivel angle)260.1 (with 90° swivel angle)---

SGD 2,100.50

SGD 1,470.35

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F12------------------------------T27--Die-cast aluminum--187.4 (at 0° swivel angle)341.9 (with 90° swivel angle)---

SGD 2,140.25

SGD 1,498.18

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel904.5-2080-2060G1/470029355.3200.8-1 - Low corrosion stressF12-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007824.5T27RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel187.4341.9Spring steel25342

SGD 2,200.45

SGD 1,540.32

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F12------------------------------T27--Die-cast aluminum--258.1 (at 0° swivel angle)470.7 (with 90° swivel angle)---

SGD 2,240.15

SGD 1,568.11

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F12------------------------------T27--Die-cast aluminum--258.1 (at 0° swivel angle)470.7 (with 90° swivel angle)---

SGD 1,660.25

SGD 1,162.18

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelSteel, nickel-plated906-2080-2060G1/470029465.5252.8Compressed air as per ISO 8573-1:2010 [7:4:4]2 - Moderate corrosion stress-----------------------------------------26268

SGD 2,081.70

SGD 1,457.19

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel906-2080-2060G1/470029465.5252.8-1 - Low corrosion stressF1012-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 2Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007824.5T27RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel258.1470.7Spring steel26268

SGD 1,632.60

SGD 1,142.82

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelSteel, nickel-plated905.5-2080-2060G1/490038842842Compressed air as per ISO 8573-1:2010 [7:4:4]2 - Moderate corrosion stress-----------------------------------------25574

SGD 2,171.35

SGD 1,519.95

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel905.5-2080-2060G1/490038842842-1 - Low corrosion stressF14-5 ... 5-5 ... 5ISO 5211AnyDouble-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 3Safety devicenanUp to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0014275.9T36RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel---25574

SGD 2,616.20

SGD 1,831.34

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F14------------------------------T36--Die-cast aluminum--179.6 (at 0° swivel angle)328.8 (with 90° swivel angle)---

SGD 2,667.00

SGD 1,866.90

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F14------------------------------T36--Die-cast aluminum--179.6 (at 0° swivel angle)328.8 (with 90° swivel angle)---

SGD 2,706.00

SGD 1,894.20

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F14------------------------------T36--Die-cast aluminum--236.1 (at 0° swivel angle)432.1 (with 90° swivel angle)---

SGD 2,756.80

SGD 1,929.76

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel904.5-2080-2060G1/490038452.8256.8-1 - Low corrosion stressF14-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 3Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007831.5T36RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel236.1432.1Spring steel28988

SGD 2,122.35

SGD 1,485.65

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelSteel, nickel-plated906-2080-2060G1/490038593.5323.6-1 - Low corrosion stressF14-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 3Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007831.5T36RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel325.1595Spring steel30395

SGD 2,840.70

SGD 1,988.49

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F14------------------------------T36--Die-cast aluminum--325.1 (at 0° swivel angle)595 (with 90° swivel angle)---

SGD 2,891.50

SGD 2,024.05

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel906-2080-2060G1/490038593.5323.6-1 - Low corrosion stressF14-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 3Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007831.5T36RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel325.1595Spring steel30194

SGD 2,661.15

SGD 1,862.81

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel906-2080-2060G1/490038593.5323.6-1 - Low corrosion stressF14-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 3Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007831.5T36RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel325.1595Spring steel30395

SGD 2,122.35

SGD 1,485.65

1 Piece(s) Quote -Anodised wrought aluminium alloy---90-----G1/4------F1012------------------------------T27--Die-cast aluminum--325.1 (at 0° swivel angle)595 (with 90° swivel angle)---

SGD 2,661.15

SGD 1,862.81

1 Piece(s) Quote 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel906-2080-2060G1/490029593.5323.6-1 - Low corrosion stressF1012-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 3Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007831.5T27RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel325.1595Spring steel30395

-

1 Piece(s) 91 Day(s) 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel903.5-2080-20601/4 NPT1601968.835.8-1 - Low corrosion stressF07-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 1Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.000785.9T17RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMHigh-alloy stainless steel33.766.6Spring steel6863

-

1 Piece(s) 91 Day(s) 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel904.5-2080-20601/4 NPT1601988.446-1 - Low corrosion stressF07-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 1Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.000785.9T17RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMHigh-alloy stainless steel43.385.7Spring steel7000

-

1 Piece(s) 91 Day(s) 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel906-2080-20601/4 NPT16019117.961.4-1 - Low corrosion stressF07-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 1Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.000785.9T17RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMHigh-alloy stainless steel57.7114.2Spring steel7206

-

1 Piece(s) 61 Day(s) 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel903.5-2080-20601/2 NPT230048916.5564-1 - Low corrosion stressF16-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 3Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007884.4T46RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel504.7857.2Spring steel72562

-

1 Piece(s) 61 Day(s) 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel904.5-2080-20601/2 NPT2300481163700.6-1 - Low corrosion stressF16-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 3Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007884.4T46RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel663.31127Spring steel74726

-

1 Piece(s) 91 Day(s) 0.2~0.8Wrought aluminum alloy, anodizedDie-cast aluminum, coatedHigh-alloy stainless steelHigh-alloy stainless steel906-2080-20601/2 NPT2300481523885.2-1 - Low corrosion stressF16-5 ... 5-5 ... 5ISO 5211AnySingle-actingGear rack/pinionClockwise closingVDI/VDE 3845 (NAMUR)VDI/VDE 3845 size AA 3Safety deviceThe safety function consists of the drive switching to the defined safety switching position when the compressed air is switched off and the spring chamber is exhausted. This switching movement is achieved by the spring force of the spring assembly.Up to SIL 2 low demand mode up to SIL 3 in a redundant architecture up to SIL 1 high demand modeProduct can be used in safety-related parts of control systems up to SIL 2, low demand Product can be used in safety-related parts of control systems up to SIL 1, high demand up to SIL 3 in a redundant architectureSee certificateas per EU explosion protection directive (ATEX)acc. to UK EX instructionsEPL Db (GB) EPL Gb (GB)Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX)DNV TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.01/2023II 2GII 2DEx h IIC T4 Gb XEx h IIIC T105°C Db X-20 <= Ta <= +80Compressed air as per ISO 8573-1:2010 [7:4:4]Dew point min. 10 °C below the ambient temperature and temperature of medium Operation with oil lubrication possible (required for further use)VDMA24364-B1/B2-L11261.01e-070.0007884.4T46RoHS-compliantWrought aluminum alloy, anodizedDie-cast aluminumPOMSteel913.21551Spring steel77972

Loading...

 

Basic Information

Seals material NBR

Tech Support