(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

3-Port Solenoid Valve, Direct Acting Type, Elastic Material Seal, Clean, Large Flow Rate Type

3-Port Solenoid Valve, Direct Acting Type, Elastic Material Seal, Clean, Large Flow Rate Type

[10-Series, Clean Series]
・ Suitable for clean environment
· It prevents dust generation in the cleanroom

(i)Caution

  • Refer to the manufacturer's catalog for specification and material details.
  • The product images are representative only. Please refer to the manufacturer's catalog for shape details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

Part Number
10-SY113A-5G-PM3-F
10-SY113A-5GZD-PM3-F
10-SY113A-5L-M3
10-SY113A-5L-PM3
10-SY113A-5L-PM3-F
10-SY113A-5LD-PM3-F
10-SY113A-5LOZ-PM3
10-SY113A-5LOZ-PM3-F
10-SY113A-5LS-PM3-F
10-SY113A-5LU-M3
10-SY113A-5LU-PM3-F
10-SY113A-5LZ-M3
10-SY113A-5LZ-M3-F
10-SY113A-5LZ-PM3
10-SY113A-5LZ-PM3-F
10-SY113A-5LZD-PM3
10-SY113A-5LZD-PM3-F
10-SY113A-5M-PM3-F
10-SY113A-5MORD-PM3
10-SY113A-5MZ-M3
10-SY113A-5MZ-PM3
10-SY113A-5MZ-PM3-F
10-SY113A-6L-M3
10-SY113A-6LD-PM3-F
10-SY113A-6LZD-M3
10-SY113A-6LZD-PM3-F
10-SY113A-SL-M3
10-SY114A-5G-M3
10-SY114A-5GZ
10-SY114A-5HZ
10-SY114A-5L
10-SY114A-5LOZE
10-SY114A-5LU
10-SY114A-5LZ
10-SY114A-5LZ-M3
10-SY114A-5LZD
10-SY114A-5LZE
10-SY114A-5LZE-M3
10-SY114A-5M-M3
10-SY114A-5MO
10-SY114A-5MOU
10-SY114A-5MOZ-M3
10-SY114A-5MS
10-SY114A-5MZ
10-SY114A-5MZ-M3
10-SY114A-5MZE
10-SY123A-5GZ-PM3-F
10-SY123A-5HS-PM3-F
10-SY123A-5HZ-PM3-F
10-SY123A-5L-PM3-F
10-SY123A-5LD-PM3-F
10-SY123A-5LR-M3
10-SY123A-5LZ-M3
10-SY123A-5LZ-M3-F
10-SY123A-5LZD-PM3
10-SY123A-5LZD-PM3-F
10-SY123A-6LD-M3
10-SY123A-6LD-PM3-F
10-SY124A-5GZD-M3
10-SY124A-5LOZD-M3
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipApplication Switching Type Voltage Mounting Orientation Pipe Port Type Plumbing Thread Nominal Plumbing Lead wire electrical entry Indicator light / Surge voltage suppressor Bracket Piping specifications Type of manual operation

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingGrommet (lead wire length: 300 mm)Without indicator light / surge voltage suppressorWith BracketFor body porting of P, R and A portsNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingGrommet (lead wire length: 300 mm)With indicator light and surge voltage suppressorWith BracketFor body porting of P, R and A portsPush-turn locking driver operation type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold BaseMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)Without indicator light / surge voltage suppressorNo bracketFor manifoldNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)Without indicator light / surge voltage suppressorNo bracketFor body porting of P, R and A portsNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)Without indicator light / surge voltage suppressorWith BracketFor body porting of P, R and A portsNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)Without indicator light / surge voltage suppressorWith BracketFor body porting of P, R and A portsPush-turn locking driver operation type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingL plug connector (without connector)With indicator light and surge voltage suppressorNo bracketFor body porting of P, R and A portsNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingL plug connector (without connector)With indicator light and surge voltage suppressorWith BracketFor body porting of P, R and A portsNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)With surge voltage suppressorWith BracketFor body porting of P, R and A portsNon-lock push type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold BaseMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressor (non-polar type)No bracketFor manifoldNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressor (non-polar type)With BracketFor body porting of P, R and A portsNon-lock push type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold BaseMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorNo bracketFor manifoldNon-lock push type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold BaseMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorWith BracketFor manifoldNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorNo bracketFor body porting of P, R and A portsNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorWith BracketFor body porting of P, R and A portsNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorNo bracketFor body porting of P, R and A portsPush-turn locking driver operation type

SGD 107.22

1 Piece(s) 32 Day(s) Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorWith BracketFor body porting of P, R and A portsPush-turn locking driver operation type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingM-type plug connector (With lead length 300 mm)Without indicator light / surge voltage suppressorWith BracketFor body porting of P, R and A portsNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingM plug connector (without connector)-No bracketFor body porting of P, R and A portsPush-turn locking driver operation type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold BaseMM3Direct PlumbingM-type plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorNo bracketFor manifoldNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingM-type plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorNo bracketFor body porting of P, R and A portsNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Direct PlumbingM-type plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorWith BracketFor body porting of P, R and A portsNon-lock push type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC12VManifold BaseMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)Without indicator light / surge voltage suppressorNo bracketFor manifoldNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC12VDirectMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)Without indicator light / surge voltage suppressorWith BracketFor body porting of P, R and A portsPush-turn locking driver operation type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC12VManifold BaseMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorNo bracketFor manifoldPush-turn locking driver operation type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC12VDirectMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorWith BracketFor body porting of P, R and A portsPush-turn locking driver operation type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC5VManifold BaseMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)Without indicator light / surge voltage suppressorNo bracketFor manifoldNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Sub-Base PlumbingGrommet (lead wire length: 300 mm)Without indicator light / surge voltage suppressorNo bracket-Non-lock push type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold Base--Sub-Base PlumbingGrommet (lead wire length: 300 mm)With indicator light and surge voltage suppressorNo bracket-Non-lock push type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold Base--Sub-Base PlumbingGrommet (Lead length 600 mm)With indicator light and surge voltage suppressorNo bracket-Non-lock push type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold Base--Sub-Base PlumbingL-shaped plug connector (With lead length 300 mm)Without indicator light / surge voltage suppressorNo bracket-Non-lock push type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold Base--Sub-Base PlumbingL plug connector (without connector)With indicator light and surge voltage suppressorNo bracket-Push-turn locking hand-operated type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold Base--Sub-Base PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressor (non-polar type)No bracket-Non-lock push type

SGD 94.03

1 Piece(s) 32 Day(s) Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold Base--Sub-Base PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorNo bracket-Non-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Sub-Base PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorNo bracket-Non-lock push type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold Base--Sub-Base PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorNo bracket-Push-turn locking driver operation type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold Base--Sub-Base PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorNo bracket-Push-turn locking hand-operated type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Sub-Base PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorNo bracket-Push-turn locking hand-operated type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Sub-Base PlumbingM-type plug connector (With lead length 300 mm)Without indicator light / surge voltage suppressorNo bracket-Non-lock push type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold Base--Sub-Base PlumbingM plug connector (without connector)Without indicator light / surge voltage suppressorNo bracket-Non-lock push type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold Base--Sub-Base PlumbingM plug connector (without connector)With indicator light and surge voltage suppressor (non-polar type)No bracket-Non-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Sub-Base PlumbingM plug connector (without connector)With indicator light and surge voltage suppressorNo bracket-Non-lock push type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold Base--Sub-Base PlumbingM-type plug connector (With lead length 300 mm)With surge voltage suppressorNo bracket-Non-lock push type

SGD 94.03

1 Piece(s) 32 Day(s) Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold Base--Sub-Base PlumbingM-type plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorNo bracket-Non-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally ClosedDC24VDirectMM3Sub-Base PlumbingM-type plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorNo bracket-Non-lock push type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally ClosedDC24VManifold Base--Sub-Base PlumbingM-type plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorNo bracket-Push-turn locking hand-operated type

-

1 Piece(s) Quote Single Use2-Position Normally OpenDC24VDirectMM3Direct PlumbingGrommet (lead wire length: 300 mm)With indicator light and surge voltage suppressorWith BracketFor body porting of P, R and A portsNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally OpenDC24VDirectMM3Direct PlumbingGrommet (Lead length 600 mm)With surge voltage suppressorWith BracketFor body porting of P, R and A portsNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally OpenDC24VDirectMM3Direct PlumbingGrommet (Lead length 600 mm)With indicator light and surge voltage suppressorWith BracketFor body porting of P, R and A portsNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally OpenDC24VDirectMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)Without indicator light / surge voltage suppressorWith BracketFor body porting of P, R and A portsNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally OpenDC24VDirectMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)Without indicator light / surge voltage suppressorWith BracketFor body porting of P, R and A portsPush-turn locking driver operation type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally OpenDC24VManifold BaseMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)-No bracketFor manifoldNon-lock push type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally OpenDC24VManifold BaseMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorNo bracketFor manifoldNon-lock push type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally OpenDC24VManifold BaseMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorWith BracketFor manifoldNon-lock push type

-

1 Piece(s) Quote Single Use2-Position Normally OpenDC24VDirectMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorNo bracketFor body porting of P, R and A portsPush-turn locking driver operation type

SGD 107.22

1 Piece(s) 32 Day(s) Single Use2-Position Normally OpenDC24VDirectMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)With indicator light and surge voltage suppressorWith BracketFor body porting of P, R and A portsPush-turn locking driver operation type

-

1 Piece(s) Quote Unit for Manifold Mounting2-Position Normally OpenDC12VManifold BaseMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)Without indicator light / surge voltage suppressorNo bracketFor manifoldPush-turn locking driver operation type

-

1 Piece(s) Quote Single Use2-Position Normally OpenDC12VDirectMM3Direct PlumbingL-shaped plug connector (With lead length 300 mm)Without indicator light / surge voltage suppressorWith BracketFor body porting of P, R and A portsPush-turn locking driver operation type

-

1 Piece(s) Quote Single Use2-Position Normally OpenDC24VDirectMM3Sub-Base PlumbingGrommet (lead wire length: 300 mm)With indicator light and surge voltage suppressorNo bracket-Push-turn locking driver operation type

-

1 Piece(s) Quote Single Use2-Position Normally OpenDC24VDirectMM3Sub-Base PlumbingL plug connector (without connector)With indicator light and surge voltage suppressorNo bracket-Push-turn locking driver operation type

Loading...

Basic Information

Number of Ports 3-Port Valve Number of Solenoids Single Specifications Lubrication Free / Clean Room
Status at Power Off Self-Recovery (Spring Return) Type Solenoid Valves Driving Type Pilot Type Spool
Pressure Rating(MPa) 0 to 0.7 Seal Type Soft Seal CV Value 0.012
Pilot Air Supply Internal

Tech Support