MELSEC-F Series Data Link/Communication (Ethernet) (Part Numbers)

Part Number

Configured Part Number is shown.

FX3U-ENET-ADP

Configured Specifications

Communication Interface (Transmission Standard)EthernetConnection TerminalConnector
Representative StandardCE / UL / CULApplicable sequencer-
Type of unitEthernet interface blockCommunication Speed(kbps)100M/10 Mbps
Transmission Speed- - -

MELSEC-F Series Data Link/Communication (Ethernet) Specifications

FX3U-ENET-ADP

FX3U-ENET-ADP Image

FX3U-ENET-ADP Image

  • By connecting a special adapter for Ethernet communication to the FX3 series basic unit, sequencers used in various devices can be easily connected to Ethernet.
  • Connecting to a network makes it feasible to monitor the status of or change the program of the sequencer from a distance, which improves maintainability.
  • Basic unit can be selected from the rich lineup of the FX3 series.

FX3U-ENET-ADP Performance Specifications

Transmission SpecificationsData Transmission Speed100 Mbps or 10 Mbps
Communication ModeFull-duplex / half-duplex
Transmission MethodBaseband
Maximum Segment Length100 m
Maximum Number of Nodes/Connections10BASE-T: Up to 4 cascade connection levels
100BASE-TX: Up to 2 cascade connection levels
The above is the number of connectable levels when using a repeater hub.
For the number of connectable levels when using a switching hub, check with the manufacturer of the switching hub to be used.
Applicable ConnectorRJ45
Function· MELSOFT connection
· Communication using MC protocol
· Direct connection with MELSOFT (easy connection)
· Connected CPU search function
· Time setting function
*Time setting function (SNTP client) can be executed only after the trigger condition is met
· Diagnostic function from MELSOFT
· Data monitoring function
Number of ConnectionsMELSOFT connection + MC protocol + data monitoring ≤ 4 connections
Number of Connectable Unit to Base UnitOne
Ethernet adapter occupies one communication channel (CH), as n communication function expansion board or other special communication adapters do.
Applicable SequencersFX3S, FX3G (V2.00 or later), FX3U (V3.10 or later), FX3GC (V2.00 or later), FX3UC (V3.10 or later):
FX3S-CNV-ADP is required to connect to the FX3S.
FX3G-CNV-ADP is required to connect to the FX3G.
A function expansion board is required to connect to an FX3U or FX3UC-32MT-LT (-2).
Weight0.1 kg
Power Supply Specifications
Power Supply30 mA / 5 V DC (Energized internally from the 5 V DC power supply of the base unit)
Allowable Momentary Power Outage DurationSame as the connected sequencer

General Specifications

Ambient Temperature0 to 55°C: When operating, -25 to 75°C: When stored
Relative Humidity5 to 95% RH (non-condensing): When operating
Vibration ResistanceWhen Mounting to DIN RailFrequency: 10 to 57 HzSingle amplitude: 0.035 mm, 10 times in each direction of X, Y and Z (total of 80 minutes each)
Frequency: 57 to 150 HzAcceleration: 4.9 m/s2 10 times in each direction of X, Y and Z (total of 80 minutes each)
When Mounting DirectlyFrequency: 10 to 57 HzSingle amplitude: 0.075 mm 10 times in each direction of X, Y and Z (total of 80 minutes each)
Frequency: 57 to 150 HzAcceleration: 9.8 m/s2 10 times in each direction of X, Y and Z (total of 80 minutes each)
Impact Resistant147 m/s2, for a duration of 11 ms, 3 times in each direction of X, Y and Z with a half-sine pulse
Noise ResistanceAchieved through a noise simulator with a noise voltage of 1,000 Vp-p, noise width of 1 μs, the rise time of 1 ns and frequency of 30 to 100 Hz
Withstand VoltageBetween all terminals batch and earth terminal: 500 V AC for 1 minute
Insulation ResistanceBetween all terminals batch and earth terminal: 5 MΩ or more with 500 V DC ohmmeter
Operating AtmosphereThere shall be no corrosion gas or flammable gas and not much conductive dust
Altitude of Use2,000 m or less
Cannot be used in environments pressurized above atmospheric pressure. This may cause failure.
Part Number
FX3U-ENET-ADP
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConnection Terminal Representative Standard Applicable sequencer Type of unit Communication Speed
(kbps)
Transmission Speed

SGD 216.40

1 Piece(s) 91 Day(s) ConnectorCE / UL / CUL-Ethernet interface block100M/10 Mbps-
Part Number
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConnection Terminal Representative Standard Applicable sequencer Type of unit Communication Speed
(kbps)
Transmission Speed
  1. 1

Basic Information

Communication Interface (Transmission Standard) Ethernet

Please check the type/dimensions/specifications of the part FX3U-ENET-ADP in the MELSEC-F Series Data Link/Communication (Ethernet) series.

Similar Part Numbers

Part Number
FX3U-ENET-L
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConnection Terminal Representative Standard Applicable sequencer Type of unit Communication Speed
(kbps)
Transmission Speed

SGD 601.60

1 Piece(s) 20 Day(s) -CE / ULFX3UC / FX3UEthernet Connection Interface-100Mbps / 10Mbps
Part Number
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConnection Terminal Representative Standard Applicable sequencer Type of unit Communication Speed
(kbps)
Transmission Speed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)