(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

CJ Series EtherNet/IP Unit

CJ Series EtherNet/IP Unit

PLC (communication unit) with a maximum tag data link capacity of 180,000 CH or more.
[Features]
・ CJ series EtherNet/IP unit
·Factory automation industry standard Ethernet. Global standard (Standardization)
・ World standard for factory automation industry with high openness and future potential
・ Industrial Ethernet, that ODVA promotes standardization around the world
・ Communicates with Omron components (temperature controllers, sensors, etc.) as well as a wide variety of equipment from companies around the world
・ No need to use differently between information LAN and dedicated control network
・ Seamless communication between control line and information monitoring line with EtherNet/IP
・ Since it is a standard LAN, it can coexist with Omron FINS message communication
・ Improve work efficiency with common tool operations
・ A large amount of tag data link can be easily done without a program just by setting a connection
・ Data can be exchanged with tag data links between up to 256 nodes using 256 connections
・ The maximum transmission/reception data capacity of 1 node is 722 CH / connection data connection can be set up to 256 connections per unit, and the total transmission/reception data can be up to 184,832 CH (There is no capacity limit on the network)
・ Guarantees data concurrency (up to 722 CH) on a per-connection basis
・ You can change the tag data link settings for individual units while using the tag data link in the network
・ With Network Configurator, you can monitor errors in the entire system with error diagnosis and a wide variety of status flags

PDF

Part Number

Configured Part Number is shown.

CJ1W-EIP21

CJ Series EtherNet/IP Unit CJ1W-EIP21/EIP21S Specifications of OMRON PLC

Appearance of CJ1W-EIP21

PLC Appearance of CJ1W-EIP21/EIP21S

Features of PLC

  • By adopting the global standard open protocol (CIP), seamless data flow between control lines and information monitoring lines can be achieved in a single network system.
  • EtherNet/IP and DeviceNet tools have unified operability.
  • The tools used for configuring, monitoring, diagnosing and transferring programs to DeviceNet and EtherNet/IP devices can be run remotely using the same operations.
  • Safety systems can be monitored.
  • The safety system can be monitored from the PLC side by combining an EtherNet/IP coupler unit and a slice-type safety control unit.
  • The convenience of universal Ethernet at your fingertips.
  • High-capacity communication via high-speed, high-capacity bus.
  • All data, from interlock information between processes and manufacturing recipes to production data, can be exchanged quickly and at the optimal timing.
  • Using an Ethernet switch, free wiring and expansion is now possible.
  • The entire network will not go down due to an abnormality in the communication path, and high-performance network performance and security can be ensured.
  • Nodes can be detached during operation, ensuring high maintainability by enabling detection, isolation, and recovery of abnormalities.
  • Unpredictable delays caused by data collisions are minimized.
  • The impact of wiring abnormalities is minimized on a line-by-line basis.
  • Reduces network installation and wiring costs.
  • A general-purpose LAN cable can be used.
  • For LAN cables, metal cables of Category 5, 5e or higher can be used.
  • A general-purpose RJ-45 connector can be used.
  • Since it is a general-purpose Ethernet, standard wireless LAN can be used.
  • There is no need to rewire when changing the layout.
  • EtherNet/IP can be made wireless using standard wireless LAN.
  • Realizes network integration of control and information from the upper level to the field level on Ethernet.
Unit
Type
namespecificationNumber of occupied
units
Current consumption (A)formatInternational
Standards
Communication CableCommunication TypeNumber of units that can be mounted per CPU5V system24V system
CJ1
CPU
High Performance
Unit
EtherNet/IP
Unit
Twisted pair cable
(shielded: STP):
Category 5, 5e or higher
Tag data link function
Message communication function
Maximum 8 units *1Unit 10.41-◎CJ1W-EIP21*2UC1,
N, L,
CE
Tag data link function
Message communication function
Socket service function
0.65◎CJ1W-EIP21S
  • *1.Up to four NJ CPU Units, up to seven CJ2H-CPU@@-EIP Units, and up to two CJ2M CPU Units can be installed.
  • *2.Toconnect the CJ1W-EIP21 to an NJ-series CPU Unit, use an EtherNet/IP Unit with unit version 2.1 or later. Also, use a CPU Unit with version 1.01 or later and a Sysmac Studio with version 1.02 or later.

About overseas standards

  • The symbols are as follows: U: UL, U1: UL (Class I Div 2 hazardous location certified product), C: CSA, UC: cULus, UC1: cULus (Class I Div 2 hazardous location certified product), CU: cUL, N: NK, L: Lloyd, CE: EC Directive.
  • For terms of use, please contact Omron's support center.

System configuration example of OMRON PLC

System configuration example

*To connect the CJ1W-EIP21 to an NJ-series CPU Unit, use an EtherNet/IP Unit with unit version 2.1 or later.
 Also, use a CPU Unit with version 1.01 or later and a Sysmac Studio with version 1.02 or later.

Wearable Devices of OMRON PLC

formatNJ SystemCJ System (CJ1, CJ2)CP1H System
CPU RackExpansion RackCPU unitAdditional EquipmentCP1H main unit
Model CJ1W-EIP214 units (per CPU) *18 units (per CPU) *22 units *3
Model CJ1W-EIP21SNoNo
  • *1.Toconnect the CJ1W-EIP21 to an NJ-series CPU Unit, use an EtherNet/IP Unit with unit version 2.1 or later. Also, use a CPU Unit with version 1.01 or later and a Sysmac Studio with version 1.02 or later.
  • *2.Up to seven CJ2H-CPU@@-EIP EtherNet/IP Units can be installed, and up to two CJ2M CPU Units can be installed.
  • *3.Requires CJ Unit Adapter CP1W-EXT01.

EtherNet/IP unit Specifications of OMRON PLC

itemspecification
formatModel CJ1W-EIP21/EIP21S
type100BASE-TX/10BASE-T (100BASE-TX is recommended) *1
Supported CPUNJ series, CJ series (CJ1, CJ2), CP1H series *2
Unit TypeCPU high-performance unit
Possible mounting positionsCPU unit or expansion unit
Number of units that can be installed *2NJ Series system: Maximum 4 units (including expansion devices)
CJ Series system: Maximum 8 units (including expansion devices) *3
CP1H system: Maximum 2 units
CPU unit occupied areaCPU high-performance unit allocation relay area25CH/unit (1st unit occupied)
Softswitch, target node PLC main unit operation/error information, unit status, communication status, registered/normal target node information, FINS/TCP connection status
CPU high-performance unit allocation DM area100CH/unit (1st unit occupied)
IP address display/setting area
User Settings AreaAny I/O memory area
Target node PLC main unit operation/abnormal information, registered/normal target node information
CPU high performance unit system setting areaNot Used
Non-volatile memory in the EtherNet/IP unitSettings are stored in the non-volatile memory of the EtherNet/IP Unit
. Note: The CPU Bus Unit system setting area in the CPU Unit is not used. This is different from the Ethernet Unit.
1) Unit settings (EtherNet/IP Unit IP address, DNS server, host name, transmission speed, FINS/UDP, FINS/TCP, and other communications settings)
2) Tag data link settings (device parameters)
3) User authentication settings (CJ1W-EIP21S only)
4) Operation log (CJ1W-EIP21S only)
Transmission SpecificationsMedia Access MethodCSMA/CD
Modulation MethodBaseband
Transmission Line TypeStar type
Transmission speed100Mbit/s (100BASE-TX)
Transmission mediumTwisted pair cable (shielded: STP): Category 5, 5e or higher
Transmission distance100m (distance between switching hub and node)
Cascade ConnectionsNo restrictions on using switching hubs
Current consumptionCJ1W-EIP21: DC5V 410mA or less
CJ1W-EIP21S: DC5V 650mA or less
massModel CJ1W-EIP21: 94g or less
Model CJ1W-EIP21S: 91g or less
External dimensions31 (W) x 90 (H) x 65 (D) mm
Other general specificationsConforms to the general specifications of the CJ series
  • *1.Whenusing tag data link, please use 100BASE-TX.
  • *2.The following CPU units are compatible with the CJ1W-EIP21S:
    CJ2H-CPU, CJ2H-CPU-EIP, CJ2M-CPU, and CJ1G-CPU4P.
  • *3.Up to seven CJ2H-CPU@@-EIP EtherNet/IP Units can be installed, and up to two CJ2M CPU Units can be installed.

Specification Table of OMRON PLC

itemspecification
When NJ CPU unit is installedWhen CJ2 CPU Unit is installedWhen CJ1 CPU Unit is installed
CIP ServiceTag data link
(cyclic communication)
Number of connections256
Packet interval
(update period)
0.5 to 10000 ms (in 0.5 ms increments)
can be set for each connection
(data is updated on the line at the set interval, regardless of the number of nodes)
Unit allowable
communication bandwidth
6000 to 12000pps *1 *2
(including heartbeat)
Number of tag sets256
Tag TypeCIO, DM, EM, HR, WR, network variables *3
Number of tags per connection
(= tag set)
8 (7 if you include controller status in the tag set)
Maximum link data
size per node
184832CH
Maximum data size
per connection
504 bytes (252CH) or 1444 bytes (722CH) *4
Data simultaneity within one connection is guaranteed.
Number of tag sets that can be registered256
(1 connection = 1 tag set)
Maximum size of one tag set722CH
(1CH is used if the tag set includes the controller status)
Maximum number of tags that can be refreshed
per cycle of the CPU unit *5
Output/transmission
(CPU → EtherNet/IP): 256
Input/reception
(EtherNet/IP → CPU): 256
Output/send
(CPU → EtherNet/IP): 19
Input/receive
(EtherNet/IP → CPU): 20 *6
Data size that can be refreshed
per cycle of the CPU unit *5 When the layoutof the allocation relay area is set to the default *7
Output/Transmission
(CPU → EtherNet/IP): 6432CH
Input/Reception
(EtherNet/IP → CPU): 6432CH
Output/Transmission
(CPU → EtherNet/IP): 7469CH
Input/Reception
(EtherNet/IP → CPU): 7469CH
On-the-fly change of tag data link
parameter settings
Possible *8
Multicast
packet filter
function *9
Yes
Explicit MessagesClass 3
(Connection-oriented)
Number of connections: 128
UCMM
(unconnected)
Maximum number of clients that can communicate simultaneously: 32
Maximum number of servers that can communicate simultaneously: 32
CIP routing *10Yes. The following units can be connected to CIP routing:
CJ1W-EIP21/EIP21S, CS1W-EIP21/EIP21S, NJ-501-□□□□, NJ-301-□□□□, CJ2H-CPU□□-EIP, CJ2M-CPU3□
FINS Service *11FINS/UDPNoYes
FINS/TCPNoMaximum 16 connections
SNMPagentSNMPv1, SNMPv2c, and SNMP traps
MIBMIB-II
EtherNet/IP Conformance TestModel CJ1W-EIP21S: CT17
Model CJ1W-EIP21: CT11
Ethernet Interface10BASE-T/100BASE-TX
Auto Negotiation/Fixed Settings
  • *1.Stands for Packet Per Second, and indicates the number of packets that can be sent or received per second.
  • *2.For CJ1W-EIP21 unit version 3.0 or later or CJ1W-EIP21S. For CJ1W-EIP21 unit version 2.1 or earlier, the limit is 6000pps.
  • *3.Network variables can only be used when installed in an NJ-series CPU, CJ2H-CPU6@-EIP or CJ2M-CPU3@, CJ2H-CPU6@ Ver.1.6 or later, or CJ2M-CPU1@ Ver.2.2 or later.
  • *4.To use a data size of 505 to 1444 bytes, the device must support Large Forward Open (CIP optional specification). It can be used between CS/CJ series devices, but when connecting to nodes from other companies, please check that thedevice supports the Large Forward Open specification.
  • *5.Ifthe maximum number is exceeded, the refresh with the CPU Unit will span multiple cycles.
  • *6.Whenthe status layout is user-defined, the maximum number is as follows:
conditionsOutput/TransmissionInput/Receive
Model CJ1W-EIP21S1818
Model CJ1W-EIP211919
  • *7.Thevalues ​​set by the user are as follows.
 When connected to a CJ1 CPU UnitWhen connected to a CJ2 CPU Unit
EIP21EIP21SEIP21EIP21S
Data size that can be refreshed per CPU unit cycleOutput/Transmission7405732163686172
Input/Receive7405738563686236
  • *8.Pleasenote that when changing parameters, the EtherNet/IP unit to be changed will be restarted. Also, in other nodes that were communicating with the unit to be changed, communication with the unit to be changed will time out once and thenautomatically return to normal.
  • *9.The EtherNet/IP Unit has an IGMP client function, so using a switching hub that supports IGMP Snooping enables filtering of unnecessary multicast packets.
  • *10.Toconnect the CJ1W-EIP21 to an NJ-series CPU Unit, use an EtherNet/IP Unit with unit version 2.1 or later. Also, use a CPU Unit with version 1.01 or later and a Sysmac Studio with version 1.02 or later.
  • *11.The EtherNet/IP unit uses the following TCP/UDP port numbers. Please set the port numbers used within TCP and UDP so that they do not overlap.
servicetypePort numbersupplement
When CJ1/CJ2 CPU Unit is installedWhen NJ CPU unit is installedWhen CJ1/CJ2 CPU Unit is installedWhen NJ CPU unit is installedWhen CJ1/CJ2 CPU Unit is installedWhen NJ CPU unit is installed
Used in the system-UDP-2223, 2224Fixed value
Tag Data LinkUDP2222
Class 3, UCMMTCP/UDP44818
DNSUDP53
BOOTP clients-UDP-68
Secure CommTCP-443-Fixed value (CJ1W-EIP21S only)
FINS/UDP ServiceUDP-9600-Can be changed in the unit settings of CX-ProgrammerCan be changed in the unit settings of Sysmac Studio.
FINS/TCP ServiceTCP-9600-
FTPTCP20, 21twenty one
SNTPUDPone two three
SNMPUDP161
SNMP trapsUDP162

Dimensional Drawing of OMRON PLC

CJ1W-EIP21 dimensional drawing

CJ1W-EIP21/EIP21S dimensional drawing

External Interface of OMRON PLC

Part Names

Part Names

  • LED display: Displays the unit status and network status.
  • Unit number setting switch: One rotary switch. Sets the unit number on the PLC body of the unit as a one-digit hexadecimal number.
  • Node address setting switches: Two rotary switches. Set the node address of the unit on the EtherNet/IP network with a two-digit hexadecimal number. Also used as the host ID part of the default IP address (192.168.250.□).
  • IP address labels: Labels for writing IP addresses and netmasks are included.
  • Ethernet connection connector (RJ45): Connect a shielded twisted pair cable to create a network.

Ethernet Connector of OMRON PLC

A connector for connecting Ethernet twisted pair cables.

  • Electrical characteristics: Compliant with IEEE802.3 standard
  • Connector Mechanism: RJ45 8-pin modular connector (ISO 8877 compliant)
Connector insertion part

Connector insertion part

Pin NumberSignal NameAbbreviationSignal Direction
1Send Data+TD+output
2Send Data -TD-output
3Received Data+RD+input
4Unused--
5Unused--
6Received Data -RD-input
7Unused--
8Unused--
Connector HoodProtective EarthFG-

Cautions and Prohibitions of OMRON PLC

  • *Rated values ​​and performance values ​​are values ​​obtained under each condition in an individual test, and values​​obtained under combined conditions of each rating value and performance value are not guaranteed.
  • *The reference data is provided for reference only, and we do not guarantee that it will always operate correctly within that range.
  • *The usage examples are for reference only and we cannot guarantee their compatibility.
  • *Product production may be discontinued or product specifications may be changed due to improvements or other reasons.
  • * Only some product information is listed.

OMRON PLC


Part Number
CJ1W-EIP21
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

SGD 2,401.85

1 Piece(s) 16 Day(s)

Loading...

  1. 1
 

Basic Information

Communication Interface (Transmission Standard) Ethernet Representative Standard CE / UL / CUL / CSA Number of Serial Numbers 1 unit's worth
Current Consumption(A) 0.41

Please check the type/dimensions/specifications of the part CJ1W-EIP21 in the CJ Series EtherNet/IP Unit series.

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)