(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
PLC (communication unit) with a maximum tag data link capacity of 180,000 CH or more.
[Features]
・ CJ series EtherNet/IP unit
·Factory automation industry standard Ethernet. Global standard (Standardization)
・ World standard for factory automation industry with high openness and future potential
・ Industrial Ethernet, that ODVA promotes standardization around the world
・ Communicates with Omron components (temperature controllers, sensors, etc.) as well as a wide variety of equipment from companies around the world
・ No need to use differently between information LAN and dedicated control network
・ Seamless communication between control line and information monitoring line with EtherNet/IP
・ Since it is a standard LAN, it can coexist with Omron FINS message communication
・ Improve work efficiency with common tool operations
・ A large amount of tag data link can be easily done without a program just by setting a connection
・ Data can be exchanged with tag data links between up to 256 nodes using 256 connections
・ The maximum transmission/reception data capacity of 1 node is 722 CH / connection data connection can be set up to 256 connections per unit, and the total transmission/reception data can be up to 184,832 CH (There is no capacity limit on the network)
・ Guarantees data concurrency (up to 722 CH) on a per-connection basis
・ You can change the tag data link settings for individual units while using the tag data link in the network
・ With Network Configurator, you can monitor errors in the entire system with error diagnosis and a wide variety of status flags
Part Number
Configured Part Number is shown.
CJ1W-EIP21
PLC Appearance of CJ1W-EIP21/EIP21S
Features of PLC
Unit Type | name | specification | Number of occupied units | Current consumption (A) | format | International Standards | |||
---|---|---|---|---|---|---|---|---|---|
Communication Cable | Communication Type | Number of units that can be mounted per CPU | 5V system | 24V system | |||||
CJ1 CPU High Performance Unit | EtherNet/IP Unit | Twisted pair cable (shielded: STP): Category 5, 5e or higher | Tag data link function Message communication function | Maximum 8 units *1 | Unit 1 | 0.41 | - | ◎CJ1W-EIP21*2 | UC1, N, L, CE |
Tag data link function Message communication function Socket service function | 0.65 | ◎CJ1W-EIP21S |
About overseas standards
*To connect the CJ1W-EIP21 to an NJ-series CPU Unit, use an EtherNet/IP Unit with unit version 2.1 or later.
Also, use a CPU Unit with version 1.01 or later and a Sysmac Studio with version 1.02 or later.
format | NJ System | CJ System (CJ1, CJ2) | CP1H System | ||
---|---|---|---|---|---|
CPU Rack | Expansion Rack | CPU unit | Additional Equipment | CP1H main unit | |
Model CJ1W-EIP21 | 4 units (per CPU) *1 | 8 units (per CPU) *2 | 2 units *3 | ||
Model CJ1W-EIP21S | No | No |
item | specification | |
---|---|---|
format | Model CJ1W-EIP21/EIP21S | |
type | 100BASE-TX/10BASE-T (100BASE-TX is recommended) *1 | |
Supported CPU | NJ series, CJ series (CJ1, CJ2), CP1H series *2 | |
Unit Type | CPU high-performance unit | |
Possible mounting positions | CPU unit or expansion unit | |
Number of units that can be installed *2 | NJ Series system: Maximum 4 units (including expansion devices) CJ Series system: Maximum 8 units (including expansion devices) *3 CP1H system: Maximum 2 units | |
CPU unit occupied area | CPU high-performance unit allocation relay area | 25CH/unit (1st unit occupied) |
Softswitch, target node PLC main unit operation/error information, unit status, communication status, registered/normal target node information, FINS/TCP connection status | ||
CPU high-performance unit allocation DM area | 100CH/unit (1st unit occupied) | |
IP address display/setting area | ||
User Settings Area | Any I/O memory area | |
Target node PLC main unit operation/abnormal information, registered/normal target node information | ||
CPU high performance unit system setting area | Not Used | |
Non-volatile memory in the EtherNet/IP unit | Settings are stored in the non-volatile memory of the EtherNet/IP Unit . Note: The CPU Bus Unit system setting area in the CPU Unit is not used. This is different from the Ethernet Unit. 1) Unit settings (EtherNet/IP Unit IP address, DNS server, host name, transmission speed, FINS/UDP, FINS/TCP, and other communications settings) 2) Tag data link settings (device parameters) 3) User authentication settings (CJ1W-EIP21S only) 4) Operation log (CJ1W-EIP21S only) | |
Transmission Specifications | Media Access Method | CSMA/CD |
Modulation Method | Baseband | |
Transmission Line Type | Star type | |
Transmission speed | 100Mbit/s (100BASE-TX) | |
Transmission medium | Twisted pair cable (shielded: STP): Category 5, 5e or higher | |
Transmission distance | 100m (distance between switching hub and node) | |
Cascade Connections | No restrictions on using switching hubs | |
Current consumption | CJ1W-EIP21: DC5V 410mA or less CJ1W-EIP21S: DC5V 650mA or less | |
mass | Model CJ1W-EIP21: 94g or less Model CJ1W-EIP21S: 91g or less | |
External dimensions | 31 (W) x 90 (H) x 65 (D) mm | |
Other general specifications | Conforms to the general specifications of the CJ series |
item | specification | ||||
---|---|---|---|---|---|
When NJ CPU unit is installed | When CJ2 CPU Unit is installed | When CJ1 CPU Unit is installed | |||
CIP Service | Tag data link (cyclic communication) | Number of connections | 256 | ||
Packet interval (update period) | 0.5 to 10000 ms (in 0.5 ms increments) can be set for each connection (data is updated on the line at the set interval, regardless of the number of nodes) | ||||
Unit allowable communication bandwidth | 6000 to 12000pps *1 *2 (including heartbeat) | ||||
Number of tag sets | 256 | ||||
Tag Type | CIO, DM, EM, HR, WR, network variables *3 | ||||
Number of tags per connection (= tag set) | 8 (7 if you include controller status in the tag set) | ||||
Maximum link data size per node | 184832CH | ||||
Maximum data size per connection | 504 bytes (252CH) or 1444 bytes (722CH) *4 Data simultaneity within one connection is guaranteed. | ||||
Number of tag sets that can be registered | 256 (1 connection = 1 tag set) | ||||
Maximum size of one tag set | 722CH (1CH is used if the tag set includes the controller status) | ||||
Maximum number of tags that can be refreshed per cycle of the CPU unit *5 | Output/transmission (CPU → EtherNet/IP): 256 Input/reception (EtherNet/IP → CPU): 256 | Output/send (CPU → EtherNet/IP): 19 Input/receive (EtherNet/IP → CPU): 20 *6 | |||
Data size that can be refreshed per cycle of the CPU unit *5 When the layoutof the allocation relay area is set to the default *7 | Output/Transmission (CPU → EtherNet/IP): 6432CH Input/Reception (EtherNet/IP → CPU): 6432CH | Output/Transmission (CPU → EtherNet/IP): 7469CH Input/Reception (EtherNet/IP → CPU): 7469CH | |||
On-the-fly change of tag data link parameter settings | Possible *8 | ||||
Multicast packet filter function *9 | Yes | ||||
Explicit Messages | Class 3 (Connection-oriented) | Number of connections: 128 | |||
UCMM (unconnected) | Maximum number of clients that can communicate simultaneously: 32 Maximum number of servers that can communicate simultaneously: 32 | ||||
CIP routing *10 | Yes. The following units can be connected to CIP routing: CJ1W-EIP21/EIP21S, CS1W-EIP21/EIP21S, NJ-501-□□□□, NJ-301-□□□□, CJ2H-CPU□□-EIP, CJ2M-CPU3□ | ||||
FINS Service *11 | FINS/UDP | No | Yes | ||
FINS/TCP | No | Maximum 16 connections | |||
SNMP | agent | SNMPv1, SNMPv2c, and SNMP traps | |||
MIB | MIB-II | ||||
EtherNet/IP Conformance Test | Model CJ1W-EIP21S: CT17 Model CJ1W-EIP21: CT11 | ||||
Ethernet Interface | 10BASE-T/100BASE-TX Auto Negotiation/Fixed Settings |
conditions | Output/Transmission | Input/Receive | |
---|---|---|---|
Model CJ1W-EIP21S | 18 | 18 | |
Model CJ1W-EIP21 | 19 | 19 |
When connected to a CJ1 CPU Unit | When connected to a CJ2 CPU Unit | ||||||
---|---|---|---|---|---|---|---|
EIP21 | EIP21S | EIP21 | EIP21S | ||||
Data size that can be refreshed per CPU unit cycle | Output/Transmission | 7405 | 7321 | 6368 | 6172 | ||
Input/Receive | 7405 | 7385 | 6368 | 6236 |
service | type | Port number | supplement | |||
---|---|---|---|---|---|---|
When CJ1/CJ2 CPU Unit is installed | When NJ CPU unit is installed | When CJ1/CJ2 CPU Unit is installed | When NJ CPU unit is installed | When CJ1/CJ2 CPU Unit is installed | When NJ CPU unit is installed | |
Used in the system | - | UDP | - | 2223, 2224 | Fixed value | |
Tag Data Link | UDP | 2222 | ||||
Class 3, UCMM | TCP/UDP | 44818 | ||||
DNS | UDP | 53 | ||||
BOOTP clients | - | UDP | - | 68 | ||
Secure Comm | TCP | - | 443 | - | Fixed value (CJ1W-EIP21S only) | |
FINS/UDP Service | UDP | - | 9600 | - | Can be changed in the unit settings of CX-Programmer | Can be changed in the unit settings of Sysmac Studio. |
FINS/TCP Service | TCP | - | 9600 | - | ||
FTP | TCP | 20, 21 | twenty one | |||
SNTP | UDP | one two three | ||||
SNMP | UDP | 161 | ||||
SNMP traps | UDP | 162 |
CJ1W-EIP21/EIP21S dimensional drawing
Part Names
A connector for connecting Ethernet twisted pair cables.
Connector insertion part
Pin Number | Signal Name | Abbreviation | Signal Direction |
---|---|---|---|
1 | Send Data+ | TD+ | output |
2 | Send Data - | TD- | output |
3 | Received Data+ | RD+ | input |
4 | Unused | - | - |
5 | Unused | - | - |
6 | Received Data - | RD- | input |
7 | Unused | - | - |
8 | Unused | - | - |
Connector Hood | Protective Earth | FG | - |
Part Number |
---|
CJ1W-EIP21 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship |
---|---|---|---|---|
SGD 2,401.85 | 1 Piece(s) | 16 Day(s) |
Loading...
Communication Interface (Transmission Standard) | Ethernet | Representative Standard | CE / UL / CUL / CSA | Number of Serial Numbers | 1 unit's worth |
---|---|---|---|---|---|
Current Consumption(A) | 0.41 |
Please check the type/dimensions/specifications of the part CJ1W-EIP21 in the CJ Series EtherNet/IP Unit series.
How can we improve?
How can we improve?