Chain Flex CF130.UL- Control Cable (CF130.05.02.UL-0.5SQ-2-94)

Chain Flex CF130.UL- Control Cable CF130.05.02.UL-0.5SQ-2-94

Features
● Supports standard loads
● PVC jacketing
● Flame retardant

Application
● For indoor use
● Particularly suited to free-span travel and sliding travel (50m max.)
● Ideal for woodworking machinery, stone processing machinery, packaging machinery, material handling equipment, automatic adjustment equipment.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

CF130.05.02.UL-0.5SQ-2-94

 
Part Number
CF130.05.02.UL-0.5SQ-2-94
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSOverall Length
(m)
Conductor Cross Section
(mm2)
Number Of Cores
(Core)
Finished outer diameter
(mm)
Rated Voltage Grounding Wire Minimum bending radius while running (Stroke Length: less than 10 m)
(mm)
Minimum bend radius while running (stroke length: More than 10 m)
(mm)
Minimum bending radius when fixed
(mm)
Conductor resistance
(Ω/km)
Reference allowable current value (30°C)
(A)

SGD 308.53

1 Piece(s) 6 Day(s) or more 10940.525.5[300V] 300/500V[NA] NA41.255527.53910

Loading...

  1. 1

Basic Information

Shield NA Representative Standard UL / CE / CSA(c-UL) Sheath (outer coating) color Gray
Sheath (outer coating) material Low adhesiveness PVC admixture Insulation body materials TPE admixture Free span maximum running speed(m/s) 3
Slide maximum running speed(m/s) 2 Maximum acceleration(m/s2) 20 Stroke Up to 50m
Twist(° (1 m)) ±90 Other standards ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2012: Used of UL (AWM) cable allowed Other cable properties Flame retardant and silicone free
Note 1 Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

Please check the type/dimensions/specifications of the part CF130.05.02.UL-0.5SQ-2-94 in the Chain Flex CF130.UL- Control Cable series.

Similar Part Numbers

Part Number
CF130.02.03.UL-0.25SQ-3-11
CF130.02.03.UL-0.25SQ-3-12
CF130.02.03.UL-0.25SQ-3-13
CF130.05.02.UL-0.5SQ-2-95
CF130.05.02.UL-0.5SQ-2-96
CF130.05.02.UL-0.5SQ-2-97
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSOverall Length
(m)
Conductor Cross Section
(mm2)
Number Of Cores
(Core)
Finished outer diameter
(mm)
Rated Voltage Grounding Wire Minimum bending radius while running (Stroke Length: less than 10 m)
(mm)
Minimum bend radius while running (stroke length: More than 10 m)
(mm)
Minimum bending radius when fixed
(mm)
Conductor resistance
(Ω/km)
Reference allowable current value (30°C)
(A)

SGD 36.74

1 Piece(s) 6 Day(s) or more 10110.2535[300V] 300/300V[NA] NA37.55025795

SGD 39.75

1 Piece(s) 6 Day(s) or more 10120.2535[300V] 300/300V[NA] NA37.55025795

SGD 42.76

1 Piece(s) 6 Day(s) or more 10130.2535[300V] 300/300V[NA] NA37.55025795

SGD 311.78

1 Piece(s) 6 Day(s) or more 10950.525.5[300V] 300/500V[NA] NA41.255527.53910

SGD 315.02

1 Piece(s) 6 Day(s) or more 10960.525.5[300V] 300/500V[NA] NA41.255527.53910

SGD 318.27

1 Piece(s) 6 Day(s) or more 10970.525.5[300V] 300/500V[NA] NA41.255527.53910

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)