[Features]
· Tank/hopper type
· Covers a wide range, from 20 kg to 5 tons, with a high accuracy of 1/5,000.
· Structure resists the effects of eccentric loads, making it ideal for weighing moving items.
· For both tensile and compression use.

(i)Caution

  • The product image is a representative image of the actual product.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

LC1205-K200

 
Part Number
LC1205-K200
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipMain applications Type Capacity
(g)
Dust-proof and waterproof function Specification details JAN Code Details of dust-proof and waterproof function Weight
(kg)
Supplement

SGD 386.75

1 Piece(s) 8 Day(s) Weighing instrumentsMain Body203900Available-4981046614016IP540.5Rated capacity (mass): 2 kN (203.9 kg), Rated output: 2.0394 mV/V±0.5%, Tolerable load: 200% of R.C., Overload limit: 200% of R.C., Overall error: 0.02% of R.O., Recommended applied voltage: 5 to 12 V DC, Zero balance: ±2% of R.O., Input terminal resistance: approx. 400 Ω, Output terminal resistance: 350±3.5 Ω, Insulator resistance: 5,000 MΩ/50 V DC, Zero point temperature influence: 0.07% of R.O./10°C, Output temperature influence: 0.02% of Load/10°C Typ., Cable thickness/length: ø6 / 3 m, Cable color: red: power source +, white: power source -, green: output +, blue: output -, yellow: shield red: power source +, white: power source -, green: output -, blue: output +, yellow: shield

Loading...

  1. 1

Please check the type/dimensions/specifications of the part LC1205-K200 in the LC-1205 Series S-Shaped General Purpose Load Cell series.

Similar Part Numbers

Part Number
LC1205-K020
LC1205-K050
LC1205-K100
LC1205-K500
LC1205-T001A
LC1205-T002
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipMain applications Type Capacity
(g)
Dust-proof and waterproof function Specification details JAN Code Details of dust-proof and waterproof function Weight
(kg)
Supplement

SGD 333.25

1 Piece(s) 8 Day(s) Weighing instrumentsMain Body20390Available-4981046613989IP540.3Rated capacity (mass): 200 N (20.39 kg), Rated output: 1.5296 mV/V±0.5%, Tolerable load: 200% of R.C., Overload limit: 250% of R.C., Overall error: 0.02% of R.O., Recommended applied voltage: 5 to 12 V DC, Zero balance: ±2% of R.O., Input terminal resistance: approx. 400 Ω, Output terminal resistance: 350±3.5 Ω, Insulator resistance: 5,000 MΩ/50 V DC, Zero point temperature influence: 0.07% of R.O./10°C, Output temperature influence: 0.02% of Load/10°C Typ., Cable thickness/length: ø6 / 3 m, Cable color: red: power source +, white: power source -, green: output +, blue: output -, yellow: shield red: power source +, white: power source -, green: output -, blue: output +, yellow: shield

SGD 332.25

1 Piece(s) 8 Day(s) Weighing instrumentsMain Body50990Available-4981046613996IP540.3Rated capacity (mass): 500 N (50.99 kg), Rated output: 1.5296 mV/V±0.5%, Tolerable load: 200% of R.C., Overload limit: 250% of R.C., Overall error: 0.02% of R.O., Recommended applied voltage: 5 to 12 V DC, Zero balance: ±2% of R.O., Input terminal resistance: approx. 400 Ω, Output terminal resistance: 350±3.5 Ω, Insulator resistance: 5,000 MΩ/50 V DC, Zero point temperature influence: 0.07% of R.O./10°C, Output temperature influence: 0.02% of Load/10°C Typ., Cable thickness/length: ø6 / 3 m, Cable color: red: power source +, white: power source -, green: output +, blue: output -, yellow: shield red: power source +, white: power source -, green: output -, blue: output +, yellow: shield

SGD 360.05

1 Piece(s) 8 Day(s) Weighing instrumentsMain Body102000Available-4981046614009IP540.4Rated capacity (mass): 1 kN (102.0 kg), Rated output: 2.0394 mV/V±0.5%, Tolerable load: 200% of R.C., Overload limit: 200% of R.C., Overall error: 0.02% of R.O., Recommended applied voltage: 5 to 12 V DC, Zero balance: ±2% of R.O., Input terminal resistance: approx. 400 Ω, Output terminal resistance: 350±3.5 Ω, Insulator resistance: 5,000 MΩ/50 V DC, Zero point temperature influence: 0.07% of R.O./10°C, Output temperature influence: 0.02% of Load/10°C Typ., Cable thickness/length: ø6 / 3 m, Cable color: red: power source +, white: power source -, green: output +, blue: output -, yellow: shield red: power source +, white: power source -, green: output -, blue: output +, yellow: shield

SGD 360.58

1 Piece(s) 8 Day(s) Weighing instrumentsMain Body509900Available-4981046614023IP540.5Rated capacity (mass): 5 kN (509.9 kg), Rated output: 2.0394 mV/V±0.5%, Tolerable load: 200% of R.C., Overload limit: 200% of R.C., Overall error: 0.02% of R.O., Recommended applied voltage: 5 to 12 V DC, Zero balance: ±2% of R.O., Input terminal resistance: approx. 400 Ω, Output terminal resistance: 350±3.5 Ω, Insulator resistance: 5,000 MΩ/50 V DC, Zero point temperature influence: 0.07% of R.O./10°C, Output temperature influence: 0.02% of Load/10°C Typ., Cable thickness/length: ø6 / 3 m, Cable color: red: power source +, white: power source -, green: output +, blue: output -, yellow: shield red: power source +, white: power source -, green: output -, blue: output +, yellow: shield

SGD 449.00

1 Piece(s) 8 Day(s) Weighing instrumentsMain Body1020000Available-4981046614030IP541.3Rated capacity (mass): 10 kN (1.020 t), Rated output: 2.0394 mV/V±0.5%, Tolerable load: 200% of R.C., Overload limit: 200% of R.C., Overall error: 0.02% of R.O., Recommended applied voltage: 5 to 12 V DC, Zero balance: ±2% of R.O., Input terminal resistance: approx. 400 Ω, Output terminal resistance: 350±3.5 Ω, Insulator resistance: 5,000 MΩ/50 V DC, Zero point temperature influence: 0.07% of R.O./10°C, Output temperature influence: 0.02% of Load/10°C Typ., Cable thickness/length: ø6 / 5 m, Cable color: red: power source +, white: power source -, green: output +, blue: output -, yellow: shield red: power source +, white: power source -, green: output -, blue: output +, yellow: shield

SGD 557.99

1 Piece(s) 8 Day(s) Weighing instrumentsMain Body2039000Available-4981046614047IP541.3Rated capacity (mass): 20 kN (2.039 t), Rated output: 2.0394 mV/V±0.5%, Tolerable load: 200% of R.C., Overload limit: 200% of R.C., Overall error: 0.02% of R.O., Recommended applied voltage: 5 to 12 V DC, Zero balance: ±2% of R.O., Input terminal resistance: approx. 400 Ω, Output terminal resistance: 350±3.5 Ω, Insulator resistance: 5,000 MΩ/50 V DC, Zero point temperature influence: 0.07% of R.O./10°C, Output temperature influence: 0.02% of Load/10°C Typ., Cable thickness/length: ø6 / 5 m, Cable color: red: power source +, white: power source -, green: output +, blue: output -, yellow: shield red: power source +, white: power source -, green: output -, blue: output +, yellow: shield

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)