(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.
  • Please be informed of our operating hours during the Chinese New Year Holidays. Click here for details.

MISUMI Control/Instrumentation Cables(Logarithm:12P)

Days to Ship
  • All
  • Same day
  • 3 Day(s) or Less
  • 4 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • 9 Day(s) or Less
  • 10 Day(s) or Less
  • 11 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Specifications
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials

    NA3VC UL Standard

      NAKVVSB 100 V or less with Shield

        NA20276HB Cross-Linked Polyethylene UL with Shield

          NA3VCSB UL Standard with Shield

          Brand

          MISUMI

          MISUMI

          MISUMI

          MISUMI

          Product Series

          NA3VC UL Standard

          NAKVVSB 100 V or less with Shield

          NA20276HB Cross-Linked Polyethylene UL with Shield

          NA3VCSB UL Standard with Shield

          Days to Ship 4 Day(s) or more 4 Day(s) or more 3 Day(s) or more 4 Day(s) or more
          Specifications
          • VW-1
          • ULAWM
          • Oil-Resistant
          • Strand Wire
          • Twisted Pair
          • 300 V
          • Oil-Resistant
          • Strand Wire
          • Single Shield
          • Twisted Pair
          • Less than 100 V
          • VW-1
          • ULAWM
          • Oil-Resistant
          • Strand Wire
          • Single Shield
          • Twisted Pair
          • 30 V
          • VW-1
          • ULAWM
          • Oil-Resistant
          • Strand Wire
          • Single Shield
          • Twisted Pair
          • 300 V
          Overall Length(m)1 ~ 1001 ~ 100-1 ~ 100
          Specified Length(m)----
          Conductor Cross Section(mm2)0.2 ~ 0.30.2 ~ 0.50.20.2 ~ 0.3
          AWG size(AWG)23 ~ 2521 ~ 252423 ~ 25
          Number Of Cores(Core)----
          Logarithm12P12P12P12P
          Finished outer diameter(mm)8.8 ~ 10.39.7 ~ 13.210.39.3 ~ 10.8
          Rated Voltage300VFor Low Current CircuitsFor Low Current Circuits300V
          ShieldNAAvailableAvailableAvailable
          PropertiesOil ResistanceOil ResistanceOil ResistanceOil Resistance
          Representative StandardUL-ULUL
          Sheath (outer coating) colorBlueBlueBlueBlue
          Grounding Wire----
          Sheath (outer coating) materialPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)
          Insulation body materialsPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)Polyethylene-BasedPVC (Polyvinyl Chloride)

          Loading...

          1. 1

          Related Categories to Control/Instrumentation Cables