(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

KVC36 UL Standard

KVC36 UL Standard

150 V Cable for UL-AWM Standard Signals

  • c-UL
  • VW-1
  • FT-1
  • ULAWM
  • Oil-Resistant
  • Strand Wire
  • Twisted Pair
  • Less than 100 V

· 1.5P sizes are not twisted pairs.
· This product is compatible with "UL Traceability Program / Processed Wire". (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* Color and softness may vary slightly due to manufacturer changes.

Electrical Appliance and Material Safety Law certificate is not obtained.

PDF

Part Number

Configured Part Number is shown.

Specifications

KVC36 UL Standard:Related Image

Model NumberSection Area
(mm2)
Number of Pairs *3
1P = 2 Cores
Total Length
or
Specified Length
Model NumberSection Area
(mm2)
Number of Pairs *3
1P = 2 Cores
Total Length
or
Specified Length
KVC36
(Twisted Pair Type)
0.21P1
~
100
(Specify 1 m
Increment)
1.5P (3-Core)
2P
3P
4P
5P
6P
7P
8P
10P
12P
15P
18P
20P
25P
30P
32P
0.31P
1.5P (3-Core)
2P
3P
4P
5P
6P
7P
8P
10P
12P
15P
18P
20P
25P
30P
32P

More Information


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
*3 Check the indications for number of cores, pair number, core / pair number, and pair number / core when  ordering.

KVC36 UL Standard:Related Image

KVC36 UL Standard:Related Image
KVC36 UL Standard:Related Image

Specifications
Model NumberSection Area
( mm2) *2
Number of Pairs *1
1P = 2 Cores
Total LengthAWG
Estimate* 2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished *5
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecification
Allowable Current
A (30°C)* 3
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Withstand Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *4Thickness
(mm)
Material *4Thickness
(mm)
Material *4
KVC36
(Twisted Pair Type)
0.21P1
~
100
(Specify 1 m
Increment)
25Twisted Pair23.1135113 or less50 or more1500
AC
7/0.180.54Tin0.255PVC1.050.5PVCULAWM2936
c-UL
1.5P (3-Core)33.31640.5
2P45.22740.85ULAWM2576
c-UL
3P65.43540.85
4P85.94030.85
5P106.35030.85
6P127.05530.9
7P147.26030.9
8P167.77030.9
10P208.58520.95
12P248.99520.95
15P309.711520.95
18P3610.513520.95
20P4011.014520.95
25P5012.517520.95
30P6013.520521
32P6413.521521
0.31P2323.720762.3 or less50 or more1500
AC
12/0.180.7N/A0.31.30.55ULAWM2936
c-UL
1.5P (3-Core)34.02560.6
2P45.73560.85ULAWM2576
c-UL
3P66.65051.0
4P87.36551.0
5P108.07541.0
6P128.89041.05
7P148.99541.05
8P169.511041.1
10P2011.014041.15
12P2411.515531.15
15P3012.518531.15
18P3613.522031.2
20P4014.023531.2
25P5015.524531.25
30P6016.534021.25
32P641736021.25


*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*5 For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.      

Current Reduction Factor
Ambient Temperature (°C)30405060708090100
Current Reduction Factor1.000.930.860.770.680.580.450.26
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 5 x 0.93 = 4.65 (A) when the ambient temperature is 40°C at 1P 0.2mm2

KVC36 UL Standard:Related Image

Wire Core Identification Table
Pair No.1234567891011
Insulator ColorBlackBlackRedRedGreenGreenYellowYellowBrownBrownBlueBlueGrayGrayOrangeOrangePurplePurpleLight GreenLight GreenPinkPink
Color of Identification Line-White-White-White-White-White-White-White-White-White-White-White
Pair No.1213141516171819202122
Insulator ColorLight BlueLight BlueWhiteWhiteGreenGreenYellowYellowBrownBrownBlueBlueGrayGrayOrangeOrangePurplePurpleLight GreenLight GreenPinkPink
Color of Identification Line-White-BlackBlackRedBlackRedBlackRedBlackRedBlackRedBlackRedBlackRedBlackRedBlackRed
Pair No.23242526272829303132  
Insulator ColorLight BlueLight BlueRedRedBlackBlackWhiteWhiteBrownBrownBlueBlueGrayGrayOrangeOrangePurplePurpleLight GreenLight Green  
Color of Identification LineBlackRedBlackGreenGreenYellowGreenYellowGreenYellowGreenYellowGreenYellowGreenYellowGreenYellowGreenYellow  

Pair No.1.5
Insulator ColorBlackBlackRed
Color of Identification Line-White-
* Wire core identification for 1.5 number of pairs (3-core strand)
Part Number
KVC36-0.2-1P-100
KVC36-0.2-2P-100
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipLogarithm Finished outer diameter
(mm)

SGD 148.95

1 Piece(s) Same day 1P3.1

SGD 236.86

1 Piece(s) Same day 2P5.2

Loading...

  1. 1

Basic Information

Overall Length(m) 100 Conductor Cross Section(mm2) 0.2 AWG size(AWG) 25
Rated Voltage 150V Shield None Properties Oil resistance
Representative Standard UL / CSA(c-UL) Sheath (outer coating) color Black Sheath (outer coating) material PVC
Insulation body materials PVC Power supply/signal Dual use Other properties Pliability

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)