(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
• Network monitoring (pressure present)
• Regulator monitoring (pressure in the setpoint range)
• Vacuum (part picked up)
• Leak test (pressure drop over time)
• Object detection (back pressure present)
A mounting concept that is quick to mount and that is easy to implement in all installation situations. Female/male thread or push-in fitting QS – the perfect pneumatic adapter for every application.
Mounting:
• Threaded mounting
• H-rail mounting
• Front panel mounting
• Mounting bracket
• Wall mounting
• Adapter to MS4, MS6
Electronics:
• Maximum versatility and reduced warehousing thanks to switchable electrical outputs (PNP/NPN/N/C contact/N/O contact and current/ voltage output)
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Operating Temperature Range (°C) | IP | Pneumatic connection | Display type | Switching output | Switching element function | Min. Temperature of medium (°C) | IP rating | DC operating voltage range (V) | Pressure measuring range initial value (bar) | Pressure measuring range end value (bar) | Max. overload pressure (bar) | Operating medium | Accuracy in ± % FS | ADC resolution | Ambient temperature | Analog output (V) | Certification | Displayable unit(s) | Electrical connection 1, connection technology | Electrical connection 1, connection type | Electrical connection 1, number of pins/wires | Electrical connection for input 1, connection pattern | Information on operating and pilot media | IO-Link®, communication mode | IO-Link®, data memory required (byte) | IO-Link®, function classes | IO-Link®, minimum cycle time (ms) | IO-Link®, port class | IO-Link®, process data content IN | IO-Link®, process data width IN (Byte) | IO-Link®, process data width OUT (Byte) | IO-Link®, profile | IO-Link®, protocol version | IO-Link®, SIO mode support | KC characters | LABS (PWIS) conformity | Max. load resistance of current output (Ohm) | Measured variable | Method of measurement | Min. load resistance of voltage output (kOhm) | Mounting position | Note on materials | Protection against tampering | Protocol | Reverse polarity protection | Rise time (ms) | Setting options | Setting range hysteresis (%) | Setting range threshold value (%) | Short-circuit protection | Switching function | Temperature co-efficient in ± %FS/K | Type of mounting | UKCA marking (see declaration of conformity) | Manufacturer part # | Weight (g) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SGD 244.40 | 1 Piece(s) | Quote | 0~50 | IP67 | G1/8 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | -1 | 1 | 5 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8001219 | 70 | ||
SGD 249.50 | 1 Piece(s) | Quote | - | - | R1/8 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | -1 | 1 | 5 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M8x1 A-coded as per EN 61076-2-104 | Plug | 4 | 991171 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With thread | To UK instructions for EMC, To UK RoHS instructions | 8001207 | 80 | ||
SGD 256.95 | 1 Piece(s) | Quote | 0~50 | IP67 | G1/8 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 2 | 6 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8001232 | 70 | ||
SGD 256.95 | 1 Piece(s) | Quote | - | - | G1/8 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 6 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M8x1 A-coded as per EN 61076-2-104 | Plug | 4 | 991171 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With wall/surface bracket | To UK instructions for EMC, To UK RoHS instructions | 8001233 | 70 | ||
SGD 266.15 | 1 Piece(s) | Quote | - | - | QS-4 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | Front panel mounting | To UK instructions for EMC, To UK RoHS instructions | 8001224 | 70 | ||
SGD 266.15 | 1 Piece(s) | Quote | 0~50 | IP67 | QS-6 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8001225 | 70 | ||
SGD 244.40 | 1 Piece(s) | Quote | 0~50 | IP67 | G1/8 | Illuminated LCD | 2xPNP or 2xNPN switchable | N/C contact, N/O contact, Switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8001221 | 70 | ||
SGD 250.80 | 1 Piece(s) | Quote | - | - | G1/8 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With H-rail | To UK instructions for EMC, To UK RoHS instructions | 8001220 | 70 | ||
SGD 234.20 | 1 Piece(s) | Quote | - | - | QS-4 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M8x1 A-coded as per EN 61076-2-104 | Plug | 4 | 991171 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With H-rail | To UK RoHS instructions, To UK instructions for EMC, To UK RoHS instructions | 8001211 | 65 | ||
SGD 240.55 | 1 Piece(s) | Quote | - | - | QS-4 | LED | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With H-rail | To UK instructions for EMC, To UK RoHS instructions | 8001212 | 65 | ||
SGD 215.00 | 1 Piece(s) | Quote | - | - | QS-4 | LED | 2xPNP | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 4 - 20 mA | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link® | IO-Link® | for all electrical connections | 3 | IO-Link® | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With H-rail | To UK instructions for EMC, To UK RoHS instructions | 8003350 | 65 | ||
SGD 215.00 | 1 Piece(s) | Quote | - | - | QS-4 | LED | 2xPNP | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link® | IO-Link® | for all electrical connections | 3 | IO-Link® | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With H-rail | To UK instructions for EMC, To UK RoHS instructions | 8003349 | 65 | ||
SGD 239.30 | 1 Piece(s) | Quote | - | - | QS-5/32 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M8x1 A-coded as per EN 61076-2-104 | Plug | 4 | 991171 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With H-rail | To UK RoHS instructions, To UK instructions for EMC, To UK RoHS instructions | 8001215 | 65 | ||
SGD 245.65 | 1 Piece(s) | Quote | - | - | QS-5/32 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With H-rail | To UK RoHS instructions, To UK instructions for EMC, To UK RoHS instructions | 8001216 | 65 | ||
SGD 293.00 | 1 Piece(s) | Quote | - | - | Flange | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M8x1 A-coded as per EN 61076-2-104 | Plug | 4 | 991171 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | On service unit | To UK RoHS instructions, To UK instructions for EMC, To UK RoHS instructions | 8035302 | 80 | ||
SGD 299.40 | 1 Piece(s) | Quote | - | - | Flange | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65 | 20 ... 30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V / 4 - 20 mA / 1 - 5 V | RCM compliance mark c UL us - Listed (OL) | MPa bar inH2O inHg kPa kgf/cm² mmHg psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC) Process data variable (PDV) IdentificationDiagnostics Teach channel | 3 | A | 14 bit PDV (pressure measurement) 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link® PIN code | IO-Link® | for all electrical connections | 3 | IO-Link® Teach-inVia display and pushbuttons | 0 ... 90 | 0 .. 100 | Yes | Freely programmable | 0.05 %FS/K | On service unit | To UK instructions for EMC To UK RoHS instructions | - | 80 | ||
SGD 293.00 | 1 Piece(s) | Quote | - | - | Flange | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M8x1 A-coded as per EN 61076-2-104 | Plug | 4 | 991171 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | On service unit | To UK RoHS instructions, To UK instructions for EMC, To UK RoHS instructions | 8035303 | 80 | ||
SGD 299.40 | 1 Piece(s) | Quote | - | - | Flange | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65 | 20 ... 30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V / 4 - 20 mA / 1 - 5 V | RCM compliance mark c UL us - Listed (OL) | MPa bar inH2O inHg kPa kgf/cm² mmHg psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC) Process data variable (PDV) IdentificationDiagnostics Teach channel | 3 | A | 14 bit PDV (pressure measurement) 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link® PIN code | IO-Link® | for all electrical connections | 3 | IO-Link® Teach-inVia display and pushbuttons | 0 ... 90 | 0 .. 100 | Yes | Freely programmable | 0.05 %FS/K | On service unit | To UK instructions for EMC To UK RoHS instructions | - | 80 | ||
SGD 246.95 | 1 Piece(s) | Quote | - | - | G1/8 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M8x1 A-coded as per EN 61076-2-104 | Plug | 4 | 991171 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With thread | To UK instructions for EMC, To UK RoHS instructions | 8001201 | 80 | ||
SGD 253.35 | 1 Piece(s) | Quote | 0~50 | IP67 | G1/8 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8001204 | 80 | ||
SGD 227.75 | 1 Piece(s) | Quote | - | - | G1/8 | LED | 2xPNP | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link® | IO-Link® | for all electrical connections | 3 | IO-Link® | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With thread | To UK instructions for EMC, To UK RoHS instructions | 8003345 | 80 | ||
SGD 249.50 | 1 Piece(s) | Quote | - | - | 1/8 NPT | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M8x1 A-coded as per EN 61076-2-104 | Plug | 4 | 991171 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With thread | To UK instructions for EMC, To UK RoHS instructions | 8001202 | 80 | ||
SGD 255.90 | 1 Piece(s) | Quote | - | - | 1/8 NPT | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With thread | To UK instructions for EMC, To UK RoHS instructions | 8001205 | 80 | ||
SGD 249.50 | 1 Piece(s) | Quote | 0~50 | IP67 | R1/4 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8001209 | 80 | ||
SGD 255.90 | 1 Piece(s) | Quote | 0~50 | IP67 | R1/4 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8001208 | 80 | ||
SGD 249.50 | 1 Piece(s) | Quote | 0~50 | IP67 | R1/8 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8001203 | 80 | ||
SGD 255.90 | 1 Piece(s) | Quote | - | - | R1/8 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With thread | To UK instructions for EMC, To UK RoHS instructions | 8001206 | 80 | ||
SGD 256.95 | 1 Piece(s) | Quote | 0~50 | IP67 | G1/8 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8001231 | 70 | ||
SGD 263.35 | 1 Piece(s) | Quote | - | - | G1/8 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With wall/surface bracket | To UK instructions for EMC, To UK RoHS instructions | 8001230 | 70 | ||
SGD 246.70 | 1 Piece(s) | Quote | - | - | QS-4 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M8x1 A-coded as per EN 61076-2-104 | Plug | 4 | 991171 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With wall/surface bracket | To UK instructions for EMC, To UK RoHS instructions | 8001237 | 65 | ||
SGD 253.10 | 1 Piece(s) | Quote | 0~50 | IP67 | QS-4 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 10 | 15 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8001236 | 65 | ||
SGD 259.75 | 1 Piece(s) | Quote | - | - | G1/8 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 16 | 20 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 2 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With H-rail | To UK instructions for EMC, To UK RoHS instructions | 8001222 | 70 | ||
SGD 258.50 | 1 Piece(s) | Quote | - | - | R1/4 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | 16 | 20 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 2 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M8x1 A-coded as per EN 61076-2-104 | Plug | 4 | 991171 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With thread | To UK instructions for EMC, To UK RoHS instructions | 8001210 | 80 | ||
SGD 266.15 | 1 Piece(s) | Quote | - | - | QS-4 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | -1 | 5 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | Front panel mounting | To UK instructions for EMC, To UK RoHS instructions | 8001227 | 70 | ||
SGD 266.15 | 1 Piece(s) | Quote | - | - | QS-6 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | -1 | 5 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | Front panel mounting | To UK instructions for EMC, To UK RoHS instructions | 8001228 | 70 | ||
SGD 271.25 | 1 Piece(s) | Quote | - | - | QS-5/32 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | -1 | 5 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | Front panel mounting | To UK instructions for EMC, To UK RoHS instructions | 8001229 | 70 | ||
SGD 244.40 | 1 Piece(s) | Quote | 0~50 | IP67 | G1/8 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | -1 | 5 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8001223 | 70 | ||
SGD 234.20 | 1 Piece(s) | Quote | - | - | QS-4 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | -1 | 5 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M8x1 A-coded as per EN 61076-2-104 | Plug | 4 | 991171 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | - | IO-Link® | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With H-rail | To UK instructions for EMC, To UK RoHS instructions | 8001213 | 65 | ||
SGD 240.55 | 1 Piece(s) | Quote | - | - | QS-4 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | -1 | 5 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | IO-Link® | for all electrical connections | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With H-rail | To UK instructions for EMC, To UK RoHS instructions | 8001214 | 65 | ||
SGD 215.00 | 1 Piece(s) | Quote | - | - | QS-4 | LED | 2xPNP | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | -1 | 5 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 4 - 20 mA | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link® | IO-Link® | for all electrical connections | 3 | IO-Link® | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With H-rail | To UK instructions for EMC, To UK RoHS instructions | 8003352 | 65 | ||
SGD 239.30 | 1 Piece(s) | Quote | - | - | QS-5/32 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | -1 | 5 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M8x1 A-coded as per EN 61076-2-104 | Plug | 4 | 991171 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | - | IO-Link® | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With H-rail | To UK instructions for EMC, To UK RoHS instructions | 8001217 | 65 | ||
SGD 227.75 | 1 Piece(s) | Quote | - | - | G1/8 | LED | 2xPNP | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | -1 | 5 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 4 - 20 mA | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | - | IO-Link® | 3 | IO-Link® | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With thread | To UK instructions for EMC, To UK RoHS instructions | 8003348 | 80 | ||
SGD 227.75 | 1 Piece(s) | Quote | - | - | G1/8 | LED | 2xPNP | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | -1 | 5 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | - | IO-Link® | 3 | IO-Link® | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With thread | To UK instructions for EMC, To UK RoHS instructions | 8003347 | 80 | ||
SGD 256.95 | 1 Piece(s) | Quote | 0~50 | IP67 | G1/8 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | -1 | 5 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8001235 | 70 | ||
SGD 263.35 | 1 Piece(s) | Quote | - | - | G1/8 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | -1 | 5 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | - | IO-Link® | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With wall/surface bracket | To UK instructions for EMC, To UK RoHS instructions | 8001234 | 70 | ||
SGD 246.70 | 1 Piece(s) | Quote | - | - | QS-4 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | - | IP65, IP67 | 20-30 | 0 | -1 | 5 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M8x1 A-coded as per EN 61076-2-104 | Plug | 4 | 991171 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | - | IO-Link® | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With wall/surface bracket | To UK instructions for EMC, To UK RoHS instructions | 8001239 | 65 | ||
SGD 253.10 | 1 Piece(s) | Quote | - | - | QS-4 | Illuminated LCD | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 0 | IP65, IP67 | 20-30 | 0 | -1 | 5 | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gas | 1.5 %FS | 12 bit | 0 °C ... 50 °C | 0 - 10 V, 4 - 20 mA, 1 - 5 V | RCM compliance mark, c UL us - Listed (OL) | Mpa, bar, inH2O, inHg, kPa, kgf/cm², mmHg, psi | M12x1 A-coded as per EN 61076-2-101 | Plug | 4 | 995386 | Operation with oil lubrication possible | COM2 (38,4 kBd) | 500 | Binary data channel (BDC), Process data variable (PDV), Identification, Diagnostics, Teach channel | 3 | A | 14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) | 2 | 0 | Smart sensor profile | Device V 1.1 | Yes | KC EMC | VDMA24364-B1/B2-L | 500 | Relative pressure | Piezoresistive pressure sensor | 10 | Any | RoHS-compliant | IO-Link®, PIN code | - | IO-Link® | 3 | IO-Link®, Teach-in, Via display and pushbuttons | 0-90 | 0-100 | yes | Freely programmable | 0.05 %FS/K | With wall/surface bracket | To UK instructions for EMC, To UK RoHS instructions | 8001238 | 65 |